Air-to-water heat pump THERMIA ATHENA 14H TOTAL +60 – 14 kW, up to 65 °C, 180 l HW + 60 l tank – SPECIAL OFFER

Code: IHPA14HT60
Action
Not rated Rating details
22 178,13 € –10 %
Tepelné čerpadlo vzduch/voda THERMIA ATHENA 14H TOTAL +60 – 14 kW, do 65 °C, TV 180 l + nádrž 60 l – AKCIA
22 178,13 € –10 % 19 960,32 € / pcs 16 227,90 € excl. VAT Measure price:
International delivery
In stock at supplier

Detailed information

Product detailed description

THERMIA ATHENA 14H TOTAL +60 (code IHPA14HT60) is a set of a premium inverter air-to-water heat pump Thermia ATHENA: the compact outdoor unit ATHENA 14H with proven refrigerant R410A and the indoor unit TOTAL +60. Model H is designed for heating and hot water preparation. The ATHENA range is suitable for new builds and renovations with heat loss up to 18 kW.

Outdoor unit ATHENA 14H

  • heating output 7.85–13.98 kW; at A7/W35 10.8 kW, at A7/W65 13.98 kW and at A-7/W35 10.14 kW
  • COP 5.09 at A7/W35, SCOP 4.7 / 3.65 at 35 / 55 °C in average climate (4.2 / 3.22 in cold climate), energy class A+++ / A++
  • EVI technology and inverter-controlled scroll compressor Copeland – water up to 65 °C, operation at outdoor temperatures from -20 to +37 °C
  • refrigerant R410A (charge 4.7 kg), electronic expansion valve, stainless steel plate condenser and energy-saving fan with EC motor and variable speed
  • sound pressure level 48 / 32 / 28 dB(A) at a distance of 1 / 5 / 10 m, dimensions 1495 × 593 × 1045 mm, weight 176.5 kg

Indoor unit TOTAL +60

Includes the control system GENESIS with a color touch display, switching valve for heating/WH, auxiliary heating, condenser and heating circulation pump, stainless steel hot water tank 180 l with TWS technology, 60 l accumulator tank connected at three points and 12 l expansion vessel. The tank provides 254 l of water at 40 °C, unit weight is 147.5 kg. Controls one direct and one mixed heating circuit, with an expansion card also pool heating. Modbus is available for higher-level building control, built-in Smart Grid function for photovoltaics and remote monitoring Thermia Online.

Design and installation

Performance is designed in the Thermia HPC program. The outdoor unit is mounted 300–500 mm in front of a wall at least 250 mm thick, which protects it from the wind; it is connected to the indoor unit by a pipe Ø 28 mm up to 15 m long. The recommended water volume in the system is 80 l. The delivery includes a magnetic filter, the connecting set IHP086U567AH is ordered separately. The indoor unit belongs to a frost-free area with a floor drain, on a floor with sufficient load capacity. Installation and commissioning is carried out by a professional company.

Technical parameters

CodeIHPA14HT60
ManufacturerTHERMIA
TypeATHENA 14H-T60
Type of heat pumpair/water, monoblock, inverter EVI
Heating capacity min.–max.7.85–13.98 kW
COP (A7/W35)5.09
SCOP 35 / 55 °C (average climate)4.7 / 3.65
Max. water temperature65 °C
Operation at outdoor temperature-20 to +37 °C
Coolingno
RefrigerantR410A, 4.7 kg
Hot water tank180 l, stainless steel, TWS + tank 60 l
Power supply400 V 3-N, 50 Hz
Sound pressure 1 / 5 / 10 m48 / 32 / 28 dB(A)
Outdoor unit (w × h × d)1495 × 593 × 1045 mm, 176.5 kg

Frequently asked questions

What is the difference between versions TOTAL, TOTAL +60 and TOTAL COMPACT?
TOTAL has a hot water tank of 300 l. TOTAL +60 has a tank of 180 l and in addition an accumulator tank of 60 l, expansion vessel of 12 l and a heating system circulation pump. TOTAL COMPACT has a tank of 180 l in a reduced cabinet.

Can the ATHENA 14H TOTAL +60 heat pump also cool?
No, model 14H is designed for heating and hot water preparation. The cooling function is available in the version marked with HC.

How far can the outdoor unit be from the indoor unit?
The units can be connected by a pipe Ø 28 mm with a maximum length of 15 m; smaller dimensions are not allowed by the manufacturer.

How noisy is the outdoor unit?
The sound pressure level is 48 dB(A) at a distance of 1 m, 32 dB(A) at 5 m and 28 dB(A) at 10 m. The manufacturer recommends not to place it near windows of living rooms or facing neighbors.

Additional parameters

Category: air / water heat pumps
Warranty: 2 years
Availability: In stock or at supplier
Code: IHPA14HT60
Manufacturer: THERMIA
Type: ATHENA 14H-T60
Heat pump type: air-to-water, monobloc, EVI inverter
Heating output min.–max.: 7.85–13.98 kW
COP (A7/W35): 5.09
SCOP 35 / 55 °C (average climate): 4.7 / 3.65
Max. water temperature: 65 °C
Outdoor temperature range: -20 to +37 °C
Cooling: no
Refrigerant: R410A, 4.7 kg
DHW cylinder: 180 l, stainless steel, TWS + 60 l buffer
Power supply: 400 V 3-N, 50 Hz
Sound pressure 1 / 5 / 10 m: 48 / 32 / 28 dB(A)
Outdoor unit (W × D × H): 1495 × 593 × 1045 mm, 176.5 kg

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.