Air-to-water heat pump THERMIA ATHENA 18HC TOTAL +60 – 18 kW, up to 65 °C, DHW 180 l + 60 l tank, with cooling – SPECIAL OFFER

Code: IHPA18HCT60
Action
Not rated Rating details
23 595,09 € –10 %
Tepelné čerpadlo vzduch/voda THERMIA ATHENA 18HC TOTAL +60 – 18 kW, do 65 °C, TV 180 l + nádrž 60 l, s chladením – AKCIA
23 595,09 € –10 % 21 235,58 € / pcs 17 264,70 € excl. VAT Measure price:
International delivery
In stock at supplier

Detailed information

Product detailed description

THERMIA ATHENA 18HC TOTAL +60 (code IHPA18HCT60) is a set of a premium inverter air-to-water heat pump Thermia ATHENA: compact outdoor unit ATHENA 18HC with proven refrigerant R410A and indoor unit TOTAL +60. The HC model is also able to cool the house – cooling works at outside temperatures from +15 to +37 °C. The ATHENA range is suitable for new builds and renovations with heat loss up to 18 kW.

Outdoor unit ATHENA 18HC

  • heating capacity 7.85–17.5 kW; at A7/W35 12.85 kW, at A7/W65 17.5 kW and at A-7/W35 12.86 kW
  • COP 5.09 at A7/W35, SCOP 4.76 / 3.67 at 35 / 55 °C in average climate (4.08 / 3.2 in cold climate), energy class A+++ / A++
  • EVI technology and inverter-controlled scroll compressor Copeland – water up to 65 °C, operation at outside temperatures from -20 to +37 °C
  • refrigerant R410A (charge 5.5 kg), electronic expansion valve, stainless steel plate condenser and energy-saving fan with EC motor and variable speed
  • sound pressure level 48 / 32 / 28 dB(A) at a distance of 1 / 5 / 10 m, dimensions 1495 × 593 × 1045 mm, weight 188 kg

Indoor unit TOTAL +60

Includes control system GENESIS with color touch display, switching valve for heating/TV, auxiliary heating, condenser and heating circulation pump, stainless steel hot water tank 180 l with TWS technology, 60 l accumulation tank connected at three points and 12 l expansion vessel. The tank provides 254 l of water at 40 °C, unit weight is 147.5 kg. Controls one direct and one mixed heating circuit, with expansion card also pool heating. Modbus is available for superior building control, built-in Smart Grid function for photovoltaics and remote monitoring Thermia Online.

Design and installation

Capacity is designed in Thermia HPC software. The outdoor unit is installed 300–500 mm in front of a wall at least 250 mm thick, which protects it from wind; it is connected to the indoor unit by a pipe Ø 28 mm up to 15 m long. Recommended water volume in the system is 120 l. The delivery includes a magnetic filter, connecting bracket IHP086U567AH is ordered separately. The indoor unit belongs to a frost-free area with floor drain, on a floor with sufficient load capacity. Installation and commissioning is carried out by a professional company.

Technical parameters

CodeIHPA18HCT60
ManufacturerTHERMIA
TypeATHENA 18HC-T60
Type of heat pumpair/water, monoblock, inverter EVI
Heating capacity min.–max.7.85–17.5 kW
COP (A7/W35)5.09
SCOP 35 / 55 °C (average climate)4.76 / 3.67
Max. water temperature65 °C
Operation at outside temperature-20 to +37 °C
Coolingyes, at +15 to +37 °C
RefrigerantR410A, 5.5 kg
Hot water tank180 l, stainless steel, TWS + 60 l tank
Power supply400 V 3-N, 50 Hz
Sound pressure 1 / 5 / 10 m48 / 32 / 28 dB(A)
Outdoor unit (w × h × d)1495 × 593 × 1045 mm, 188 kg

Frequently asked questions

What is the difference between versions TOTAL, TOTAL +60 and TOTAL COMPACT?
TOTAL has a hot water tank of 300 l. TOTAL +60 has a tank of 180 l and in addition an accumulation tank of 60 l, expansion vessel of 12 l and a heating system circulation pump. TOTAL COMPACT has a tank of 180 l in a reduced cabinet.

Can the heat pump ATHENA 18HC TOTAL +60 also cool?
Yes, the HC model has a built-in cooling function, which works at outside temperatures from +15 to +37 °C. It controls a switching valve for cooling/heating, through which a cooling tank can be connected.

How far can the outdoor unit be from the indoor unit?
The units can be connected by a pipe Ø 28 mm with a maximum length of 15 m; smaller dimensions are not allowed by the manufacturer.

How noisy is the outdoor unit?
The sound pressure level is 48 dB(A) at a distance of 1 m, 32 dB(A) at 5 m and 28 dB(A) at 10 m. The manufacturer recommends not to place it near windows of living rooms or facing neighbors.

Additional parameters

Category: air / water heat pumps
Warranty: 2 years
Availability: In stock or at supplier
Code: IHPA18HCT60
Manufacturer: THERMIA
Type: ATHENA 18HC-T60
Heat pump type: air-to-water, monobloc, EVI inverter
Heating output min.–max.: 7.85–17.5 kW
COP (A7/W35): 5.09
SCOP 35 / 55 °C (average climate): 4.76 / 3.67
Max. water temperature: 65 °C
Outdoor temperature range: -20 to +37 °C
Cooling: yes, at +15 to +37 °C
Refrigerant: R410A, 5.5 kg
DHW cylinder: 180 l, stainless steel, TWS + 60 l buffer
Power supply: 400 V 3-N, 50 Hz
Sound pressure 1 / 5 / 10 m: 48 / 32 / 28 dB(A)
Outdoor unit (W × D × H): 1495 × 593 × 1045 mm, 188 kg