Air-to-water heat pump Thermia ITEC E-STANDARD 8 (ITEC E-S 8) – 1.7–8 kW, output up to 65 °C
Code: IHP086L4755Product detailed description
ITEC E-STANDARD 8 (ITEC E-S 8) is an inverter heat pump from Thermia's IVAR.HP iTec E series for single-family homes and apartments – both new constructions and renovated buildings with a heat loss up to 19 kW. It consists of an external compact unit with a power of 1.7–8 kW and an internal unit in the STANDARD version. The frequency inverter continuously adjusts the output to the current heat loss of the house.
Internal unit STANDARD
The STANDARD version includes only the control system with a display – a cabinet of 380 × 204 × 600 mm with a weight of 18 kg, power supply 230 V, circuit breaker 10 A. The circulation pump, switching valve, auxiliary heater, and hot water tank are not part of it and are resolved according to the project. It is mainly used in renovations where the original components remain in the system, or in new buildings without hot water preparation by the heat pump.
Performance and efficiency
- SCOP 4.45 at 35 °C (floor heating) and 3.23 at 55 °C (radiators) for an average climate
- COP 4.52 at A7/W35, energy class A+++ at 35 °C and A++ at 55 °C
- water output temperature +15 to +65 °C, heating and hot water heating down to an outside temperature of −25 °C
- cooling in the basic equipment – 7.9 kW at A35/W18 (SEER 4.52), including a signal for the cooling/heating switching valve
- refrigerant R32 with GWP 675 (charge 1.15 kg), dual rotary BLDC compressor, electronic expansion valve, stainless steel plate condenser
External unit
Dimensions 940 × 330 × 998 mm (w × h × d), weight 76 kg, heating water connections 1" with external thread. Power supply 400 V 3~N 50 Hz, circuit breaker 10 A. Sound pressure level at a distance of 4 m is 46 dB(A), sound power 63 dB(A). The unit must be mounted on a solid foundation and must not be placed in an enclosed space; condensate from defrosting is drained via a heated pipe, never into the sewer.
System design
- at least 180 l of heating water must always be available in the system for safe defrosting
- rated flow 7 l/min, pipe size min. 28 mm; flow sensor is part of the delivery
- control handles direct and mixing circuits, with an expansion card a second mixing circuit or pool heating
- cooperation with photovoltaics via Smart Grid (optional accessories), it is recommended to use the HPC software for dimensioning
Installation: Installation, electrical connections, and work on the refrigerant circuit with slightly flammable refrigerant R32 may only be performed by qualified professionals.
Technical parameters
| Code | IHP086L4755 |
| Manufacturer | Thermia (IVAR.HP iTec E series) |
| Type | ITEC E-S 8 |
| Internal unit | STANDARD – control system |
| Heating capacity | 1.7–8 kW |
| Cooling capacity (A35/W18) | 7.9 kW |
| SCOP 35 °C / 55 °C (average climate) | 4.45 / 3.23 |
| COP (A7/W35) | 4.52 |
| Energy class 35 °C / 55 °C | A+++ / A++ |
| Water output temperature | +15 to +65 °C |
| Outside temperature for heating | −25 to +35 °C |
| Refrigerant | R32, 1.15 kg |
| External unit power supply | 400 V 3~N 50 Hz |
| Sound pressure level at 4 m | 46 dB(A) |
| External unit w × h × d, weight | 940 × 330 × 998 mm, 76 kg |
Frequently asked questions
What is included in the delivery?
External unit with condensate drain elbow, internal unit STANDARD, ball valve with filter, external temperature sensor, flow sensor, and documentation. Connection piping and flexible hoses are ordered separately as accessories.
Does the STANDARD version also prepare hot water?
The internal unit STANDARD includes only the control system, it does not have a circulation pump, switching valve, or a tank – these components are added according to the project. If you want the components for hot water preparation in one cabinet, choose the PLUS version (with a separate tank) or TOTAL.
Can the heat pump also cool?
Yes, the cooling function is already included in the basic version, with a cooling capacity of 7.9 kW at A35/W18. Cooling circuits must be insulated with vapor-tight insulation to prevent condensation of moisture on them.
What maintenance does the heat pump require?
Check the pressure in the heating system monthly (0.8–1.5 bar), safety valves at least four times a year, and clean the dirt filter twice a year. Keep the external unit free of snow, ice, and leaves.
Additional parameters
| Category: | air / water heat pumps |
|---|---|
| Warranty: | 2 years |
| Availability: | In stock or at supplier |
| Code: | IHP086L4755 |
| Manufacturer: | Thermia (IVAR.HP iTec E range) |
| Type: | ITEC E-S 8 |
| Indoor unit: | STANDARD – control system |
| Heating output: | 1.7–8 kW |
| Cooling output (A35/W18): | 7.9 kW |
| SCOP 35 °C / 55 °C (average climate): | 4.45 / 3.23 |
| COP (A7/W35): | 4.52 |
| Energy class 35 °C / 55 °C: | A+++ / A++ |
| Flow temperature: | +15 to +65 °C |
| Outdoor temperature for heating: | −25 to +35 °C |
| Refrigerant: | R32, 1.15 kg |
| Outdoor unit power supply: | 400 V 3~N 50 Hz |
| Sound pressure level at 4 m: | 46 dB(A) |
| Outdoor unit W × D × H, weight: | 940 × 330 × 998 mm, 76 kg |
Product rating
Be the first who will post an article to this item!
Discussion