Air-to-water heat pump Thermia ITEC E-TOTAL 16 (ITEC E-T 16) – 3.4–16 kW, output up to 65 °C – SPECIAL OFFER – SALE
Code: IHP086L4750Product detailed description
ITEC E-TOTAL 16 (ITEC E-T 16) is an inverter heat pump from Thermia's IVAR.HP iTec E series for single-family homes and apartments – both new constructions and renovated buildings with heat loss up to 19 kW. It consists of an external compact unit with a power of 3.4–16 kW and an internal unit in the TOTAL version. The compressor frequency converter continuously adjusts the performance to the current heat loss of the house.
Internal unit TOTAL
The TOTAL version includes a control system, sensors for supply and return, a circulation pump with speed regulation, a switching valve for heating/hot water, an auxiliary heater of 15 kW (supply 400 V), and a stainless steel hot water tank with a volume of 180 l with a TWS coil. The cabinet has dimensions of 596 × 690 × 1845 mm and weighs 106 kg when empty. Hot water has priority over heating, and the tank is regularly heated against legionella (once every 7 days from the factory).
Performance and efficiency
- SCOP 4.48 at 35 °C (floor heating) and 3.53 at 55 °C (radiators) for average climate
- COP 4.42 at A7/W35, energy class A+++ at 35 °C and A++ at 55 °C
- water output +15 to +65 °C, heating and hot water heating down to an outside temperature of −25 °C
- cooling in the basic equipment – 14 kW at A35/W18 (SEER 5.31), including a signal for the cooling/heating switching valve
- refrigerant R32 with GWP 675 (charge 2.2 kg), dual BLDC rotary compressor, electronic expansion valve, stainless steel plate condenser
External unit
Dimensions 940 × 330 × 1420 mm (w × h × d), weight 111 kg, heating water connections 1" with external thread. Supply 400 V 3~N 50 Hz, circuit breaker 16 A. Sound pressure level at a distance of 4 m is 49 dB(A), sound power 66 dB(A). The unit is mounted on a solid foundation and must not be placed in an enclosed space; condensate from defrosting is drained via a heated pipe, never into the sewer.
System design
- at least 160 l of heating water must always be available in the system for safe defrosting
- rated flow 16 l/min, pipe size min. 35 mm; flow sensor is part of the delivery
- control handles direct and mixed circuits, with an expansion card a second mixed circuit or pool heating
- cooperation with photovoltaics via Smart Grid (optional accessories), it is recommended to use the HPC software for dimensioning
Installation: Only qualified professionals may perform installation, electrical connections, and interventions in the refrigerant circuit with the slightly flammable refrigerant R32.
Technical parameters
| Code | IHP086L4750 |
| Manufacturer | Thermia (series IVAR.HP iTec E) |
| Type | ITEC E-T 16 |
| Internal unit | TOTAL – equipment PLUS and hot water tank 180 l |
| Heating power | 3.4–16 kW |
| Cooling power (A35/W18) | 14 kW |
| SCOP 35 °C / 55 °C (average climate) | 4.48 / 3.53 |
| COP (A7/W35) | 4.42 |
| Energy class 35 °C / 55 °C | A+++ / A++ |
| Water temperature at output | +15 to +65 °C |
| Outside temperature for heating | −25 to +35 °C |
| Refrigerant | R32, 2.2 kg |
| External unit power supply | 400 V 3~N 50 Hz |
| Sound pressure level at 4 m | 49 dB(A) |
| External unit w × h × d, weight | 940 × 330 × 1420 mm, 111 kg |
Frequently asked questions
What is included in the delivery?
External unit with condensate drain elbow, internal unit TOTAL, ball valve with filter, external temperature sensor, flow sensor and documentation. Connection piping and flexible hoses must be ordered separately as accessories.
How much hot water does the TOTAL version prepare?
The built-in stainless steel tank has a volume of 180 l. According to EN 16147, it provides 245 l of water at 40 °C with this heat pump size.
Can the heat pump also be used for cooling?
Yes, the cooling function is included in the basic version, with a cooling capacity of 14 kW at A35/W18. Cooling circuits must be insulated with vapor-tight insulation to prevent condensation of moisture on them.
What maintenance does the heat pump require?
Check the pressure in the heating system monthly (0.8–1.5 bar), safety valves at least four times a year, and clean the dirt filter twice a year. Keep the external unit free of snow, ice, and leaves.
Additional parameters
| Category: | air / water heat pumps |
|---|---|
| Warranty: | 2 years |
| Availability: | In stock or at supplier |
| Code: | IHP086L4750 |
| Manufacturer: | Thermia (IVAR.HP iTec E range) |
| Type: | ITEC E-T 16 |
| Indoor unit: | TOTAL – PLUS equipment and 180 l DHW cylinder |
| Heating output: | 3.4–16 kW |
| Cooling output (A35/W18): | 14 kW |
| SCOP 35 °C / 55 °C (average climate): | 4.48 / 3.53 |
| COP (A7/W35): | 4.42 |
| Energy class 35 °C / 55 °C: | A+++ / A++ |
| Flow temperature: | +15 to +65 °C |
| Outdoor temperature for heating: | −25 to +35 °C |
| Refrigerant: | R32, 2.2 kg |
| Outdoor unit power supply: | 400 V 3~N 50 Hz |
| Sound pressure level at 4 m: | 49 dB(A) |
| Outdoor unit W × D × H, weight: | 940 × 330 × 1420 mm, 111 kg |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!