Atmos A25 Burner Combustion Chamber

Code: H0228
Not rated Rating details
140,20 € / pcs 113,98 € excl. VAT Measure price:
International delivery
In stock now (1 pcs)

Detailed information

Product detailed description

Combustion chamber H0228 for Atmos A25 pellet burner

Code H0228 designates a replacement combustion chamber, in practice the cup or bowl of a pellet burner. The part belongs to the group of spare parts for pellet burners and augers. It is intended for Atmos A25 burners with serial number 160 and higher.

ParameterValue
Part codeH0228
Partcombustion chamber (burner cup)
ApplicationAtmos A25 pellet burner
Burner serial numberfrom 160
Burner cleaningwithout pneumatic cleaning

Note the version with pneumatic cleaning

This chamber does not fit a burner that is cleaned by a compressor. If you have an Atmos A 25 pellet burner with pneumatic cleaning, order the chamber for the Atmos A 25 burner with pneumatic cleaning instead.

Before ordering, therefore, check which version of the burner you have and what its serial number is.

Frequently asked questions

  • How do I choose the right output for a solid fuel boiler? Base it on the calculated heat loss of the heated building. With wood/coal boilers, however, also consider that the boiler burns for several hours per load at essentially constant output - which is why it is common practice to add an accumulation tank to the boiler, which stores the excess heat for later use instead of the boiler having to be throttled down inefficiently.
  • What else do I need to install this boiler? Besides the boiler itself, the system usually requires: an accumulation (buffer) tank of suitable volume, a circulation pump (often already with a built-in Laddomat or a thermostatic valve protecting the boiler against low-temperature corrosion), a safety valve, an expansion vessel and a flue/chimney with sufficient draught matching the boiler output - you will find the exact chimney draught values in the technical parameters above.
  • Which fuel is suitable and which is not? Use only the fuel recommended by the manufacturer for the given model (usually logs of defined length and moisture content, or brown coal briquettes or coal, depending on the boiler type) - unsuitable or overly moist fuel reduces efficiency, increases the formation of tar and deposits, and may damage the boiler.
  • What about the chimney inspection and legislation? Before the boiler is put into operation, and also regularly during its use (usually once a year for solid fuels), an inspection/cleaning of the chimney by an authorized chimney sweep is required by law - without the relevant inspection certificate, an insurance claim in the event of a fire may also be disputed.
  • How much maintenance does the boiler require? It usually includes regular ash removal and cleaning of the heat exchange surfaces/flue gas passages of soot (the interval depends on the intensity of use, usually in the order of weeks), and a thorough inspection once a year, including the seals and the chimney.
  • Can I install the boiler myself? The positioning and connection of the boiler to the heating system, the chimney and the safety components should be carried out, or at least professionally checked, by a heating technician - this is an appliance with an open fire, high temperatures and pressure components, where a mistake in the connection can pose a safety risk.

Additional parameters

Category: spare parts for pellet burner
Warranty: 2 years
Weight: 0.966 kg

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field

Company History

The family company ATMOS was founded in the Czech Republic in 1935. In the beginning, production was focused on gasifier power units for cars and boats under the brand name DOKOGEN, i.e. the same principle used in modern gasifier boilers for wood and coal.

 
 
 

Despite the German occupation and communist dictatorship, it was possible to maintain the development of wood boilers, gasifier units and compressors. In 1980, at the Pragotherm exhibition, the first wood gasifier boilers and wood waste boilers were presented. To date, 90 types of hot water boilers have been developed, for which the company holds 15 patents. One of the first developed boilers was the EKONOMIK boiler in 1968.

 

 

To ensure the European market with quality boilers that save the environment and energy, three generations of the Cankář family are currently working in the family business. The founder of the company, Jaroslav Cankář senior, passed away in March 2006 at the age of 94.

Company ATMOS – present

Atmos is a Czech family company and currently one of the largest European manufacturers of solid fuel boilers. The company exports more than 60% of its production abroad, mainly to Germany, Austria, Sweden, Italy, France, Romania, Poland, Bulgaria, Denmark, Slovakia, Lithuania, Latvia, Ukraine, Belarus, Spain, the United Kingdom, etc.

 

The product range includes solid fuel boilers, gasification boilers for wood from 15 to 150 kW, gasification boilers for brown coal (and wood) from 16 to 48 kW, gasification boiler for brown coal briquettes and black coal with a power of 16 and 26 kW, automatic pellet boilers from 4.5 to 80 kW and combined boilers for gasification of wood in combination with a pellet burner in power from 20 to 35 kW. Products of the company Atmos have aroused great interest among users heating with wood and installers, due to their good functionality, quality and, last but not least, very favorable price.

The goal of the company ATMOS is to be one of the best boiler manufacturers in Europe. To be a company that values its tradition, experience and the ATMOS brand

Vytvořil Shoptet | Design Shoptak.cz.