ATTACK AK 3000 Storage Tank (insulation included in price)

Code: AK3000K
Not rated Rating details
3 255 € –5 %
ATTACK Akumulačná nádrž AK 3000 (izolácia v cene)
3 255 € –5 % 3 092,25 € / pcs 2 514,02 € excl. VAT Measure price:
International delivery
To order

Detailed information

Product detailed description

Why a buffer tank determines heating efficiency

ATTACK Buffer Tank AK 3000 (insulation included in price) is a steel accumulation (buffer) tank with a volume of 3000 litres, designed for storing hot heating water from any heat source - a wood gasification boiler, heat pump, electric boiler, gas boiler or solar collectors. It is a tank without a built-in heat exchanger (sometimes also referred to as a "hydraulic separator" or "buffer tank"), which serves purely for storing heating water - heating of domestic hot water (DHW) with this type of tank is solved externally, for example through a storage water heater or a flow module.

The biggest benefit of a buffer tank can be seen when combined with a solid fuel gasification boiler, such as the ATTACK DPX or ATTACK SLX. These boilers achieve the highest efficiency and cleanest combustion precisely when they burn at full, rated output - that is, when they burn a full load of wood "in one go" without throttling the air supply. Without a buffer tank, the boiler would often have to operate in a choked mode (to avoid overheating the system), which leads to worse combustion, higher tar formation, and shorter boiler and chimney lifespan. With the ATTACK Buffer Tank AK 3000 (insulation included in price), the boiler burns the fuel at full output at once and the surplus heat is stored in the water reserve in the tank - from there, the heating system gradually draws it as needed by the household, even several hours after the boiler has burned out.

The same principle also works with an electric boiler or heat pump: the 3000 l tank allows the heat source to operate in longer, less frequent cycles instead of constantly switching on and off for short intervals, which extends the lifespan of the compressor/heating elements and reduces energy consumption. This is a large-volume industrial/commercial buffer tank, designed for larger boiler rooms, agricultural operations, dryers, guesthouses or apartment buildings with a central heat source, where heat from multiple boilers or from a high-capacity gasification boiler needs to be stored for a longer period.

Key features of the AK3000K tank

  • Volume of 3000 litres - designed so that, with the recommended heat source output of 120 - 150 kW, it provides a sufficient heat reserve between heating cycles.
  • Soft, removable polyester insulation 100 mm thick - significantly reduces heat loss to the surroundings during long-term storage of hot water, while being easy to unfasten for inspection or servicing of the tank and its fittings.
  • Outer cover of the insulation made of leatherette (PVC fabric) in silver-grey - resistant to abrasion and easy to maintain, visually blending into the boiler room interior rather than looking like a "technical" element.
  • 6 connection fittings distributed around the shell and on the top/bottom side of the tank, allowing connection of the heat source, heating circuits, an additional electric heating element (backup heating), venting, draining and temperature sensors.
  • Steel shell with a corrosion-resistant internal surface treatment, designed for a maximum operating pressure of 3 bar and a maximum temperature of 95 °C - a safe margin compared to typical operating temperatures of heating water (60-80 °C).
  • Suitable for vertical position thanks to feet/a stand, which at this volume facilitates precise temperature layering (stratification) - warmer water naturally stays at the top, cooler water at the bottom, increasing the usable amount of accumulated heat.
  • Possibility of additional installation of an electric heating element (e.g. ATTACK TH100, TH102, TH103 or TH107) directly into one of the tank fittings - suitable as a backup or supplementary heat source outside the heating season or in case of failure of the main source.
  • Without a built-in heat exchanger - the tank is designed purely for accumulating heating water; if you also need to prepare DHW via a built-in heat exchanger, check out our range of AS/HR/HRS/TUV/TUVS tanks with heat exchanger.

Technical parameters

Tank volume3000 l
Tank diameter (without insulation)~1400 mm (estimate)
Tank diameter (with insulation)~1600 mm (estimate)
Tank height~2450 mm (estimate)
Weight of empty tank~250 kg (estimate)
Tank materialSteel
InsulationSoft, removable, polyester, 100 mm thick
Insulation coloursilver-grey
Number of connection fittings6 pcs
Max. operating pressure3 bar
Max. operating temperature95 °C
Recommended heat source output120 - 150 kW
Heat exchangerNo (tank without heat exchanger)
Country of originSlovakia
ManufacturerATTACK s.r.o.
Warranty24 months from commissioning, max. 30 months from dispatch

Note: the dimensions and weight of the empty tank are approximate estimates corresponding to the given volume; before installation (e.g. in case of limited space in the boiler room or narrow doors/staircase), we recommend verifying the exact dimensions directly with the seller before ordering.

How to choose the right buffer tank volume correctly

The most common recommended rule when selecting a buffer tank for a solid fuel gasification boiler is: allow approximately 20 to 25 litres of buffer volume for each 1 kW of rated boiler output. This rule is based on the fact that the boiler burns one load of fuel at full output in approximately 1.5 to 3 hours, and the heat from this load needs to be stored somewhere until the heating system gradually consumes it. With a tank volume of 3000 litres, this means it is suitable for a heat source with an output of approximately 120 to 150 kW.

If you have, for example, a wood gasification boiler with an output in this range (from the ATTACK range, these are for example some models from the DPX or SLX series - both Standard and Profi versions), the tank ATTACK Buffer Tank AK 3000 (insulation included in price) is appropriately sized for your system. For a higher boiler output, or if you plan to combine multiple heat sources (e.g. a wood boiler + heat pump, or a boiler + solar collectors), we recommend choosing a larger volume, or possibly connecting multiple tanks in a cascade - so that the buffer volume matches the sum of the outputs of the connected sources.

With a volume of 3000 l, it also holds true that the larger the tank, the longer it can supply heat even after the boiler has completely burned out - with a well-designed and sufficiently large system, it is common for a family house to be able to heat for 12 to 24 hours from a single boiler load and one buffer tank, depending on the outdoor temperature, the heat losses of the house and the temperature gradient of the heating system (lower temperatures, e.g. with underfloor heating, allow a greater portion of the stored heat to be used than high-temperature radiator systems).

It is also worth remembering that a buffer tank is worthwhile in combination with automatic heat sources, such as an electric boiler or heat pump - although these sources can modulate output more smoothly than a solid fuel boiler, they still benefit from the tank by reducing the number of switching cycles, which saves the lifespan of the compressor, circulation pumps and electronics.

Connection, installation and backup heating options

The ATTACK Buffer Tank AK 3000 (insulation included in price) is typically connected as a hydraulically separated buffer element between the heat source and the heating system (radiators, underfloor heating, fan-coil units, etc.) - the heat source charges the tank via one pair of fittings, while the heating system draws heat via another pair, hydraulically separating both circuits so the system operates more stably even with fluctuating flow on the source side. The remaining fittings (a total of 6 on this tank) are used, for example, for installing a temperature sensor, air vent valve, safety valve, or for connecting an additional electric heating element.

The option to install an electric heating element is a practical solution for periods when you do not want to heat with solid fuel (e.g. outside the main heating season) or as a backup in case of failure of the main source. Our range includes electric heating elements ATTACK TH100 (2.5 kW), TH102 (4.5 kW), TH103 (6 kW) and TH107 (2 kW), all with their own thermostat and G6/4" thread - compatible with the fittings of this buffer tank. We recommend choosing the element's output based on the tank volume and the required heating-up speed.

When installing the ATTACK Buffer Tank AK 3000 (insulation included in price), make sure there is sufficient manoeuvring space in the boiler room - given a diameter with insulation of approximately 1600 mm and a height of approximately 2450 mm (both values are approximate, see above), it is necessary to check in advance the clearance of doors, staircases and the room itself. We also recommend leaving a free space of at least 300-500 mm around the tank on the side with the connection fittings, to ensure comfortable access for servicing, gasket replacement or checking/topping up sensors.

We recommend filling the tank only with treated heating water in accordance with the applicable standard (e.g. STN EN 14868 or the boiler manufacturer's recommendation) - hard water with a high mineral content accelerates limescale formation on the internal walls and shortens the lifespan of the whole system, including the boiler and circulation pumps.

Connection with other heating system components

The ATTACK Buffer Tank AK 3000 (insulation included in price) forms only one link in the heating chain. Customers most often combine it with the wood gasification boiler ATTACK DPX or ATTACK SLX (Standard and Profi versions, output range approximately 15-35 kW), with the boiler's output matching the recommended range of 120-150 kW mentioned above. When combined with a heat pump or electric boiler, the tank serves as a hydraulic separator and heat store reducing the number of switching cycles of the source. If you also need to prepare domestic hot water, since this particular tank is a version without a heat exchanger, we recommend supplementing the system with a separate DHW storage water heater (e.g. from the ATTACK Z range - Z100, Z125, Z160, Z200 and others, available in our range), or choosing one of the models from the AS/HR/HRS/TUV/TUVS range instead of this tank, which have a heat exchanger built directly into the tank.

Maintenance and inspection of the tank during operation

The ATTACK Buffer Tank AK 3000 (insulation included in price) requires minimal but regular maintenance. We recommend checking once a year (for example before the start of the heating season) the tightness of all 6 connection fittings, the condition of the air vent valve and the heating circuit safety valve, as well as the overall condition of the outer insulation cover - the leatherette cover in silver-grey is resistant to normal abrasion, but in case of mechanical damage (e.g. during moving or handling in the boiler room), we recommend repairing the damaged spot in time to avoid unnecessary heat losses.

Since this is a tank without a built-in heat exchanger, the inside of the tank only comes into contact with treated heating water, not with drinking water - the risk of limescale buildup is thus significantly lower than with DHW storage tanks, but we still recommend visually inspecting the inside of the tank through the inspection opening (if the model has one) once every few years (for example during a system shutdown), or at least monitoring the quality and colour of the heating water when desludging the system. Cloudy or rusty water may indicate the need for water treatment or a check for corrosion in the system.

During long-term shutdown (e.g. outside the heating season), it is not necessary to drain the tank - on the contrary, leaving water in the system protects the internal surface from corrosion caused by exposure to air. If you plan to take the tank completely out of operation for a longer period, consult a qualified installer about the appropriate preservation procedure.

Frequently Asked Questions

Do I need to buy a heat exchanger for this tank as well?

No, this AK3000K model cannot be additionally fitted with a built-in heat exchanger - it serves purely for accumulating heating water. If you need to prepare domestic hot water via a heat exchanger in the same tank, choose from our AS, HR, HRS, TUV or TUVS range.

How big a boiler can I connect to this tank?

For a volume of 3000 litres, we recommend a heat source with an output of approximately 120 to 150 kW, according to the rule of 20-25 litres of accumulation per 1 kW of output. For a more powerful source, it is preferable to choose a larger volume or connect multiple tanks in a cascade.

Can the tank also be used with a heat pump or electric boiler?

Yes, the AK3000K buffer tank works equally well with a heat pump, electric boiler, gas boiler or solar collectors - in every case it reduces the number of switching cycles of the source and balances the differences between heat production and consumption.

Is insulation included in the delivery?

Yes, the tank is supplied including soft, removable polyester insulation 100 mm thick with an outer cover made of leatherette in silver-grey.

Can I install an electric heating element for backup heating into the tank?

Yes, the tank has 6 connection fittings, one of which can be used to install an electric heating element, for example ATTACK TH100, TH102, TH103 or TH107 with a G6/4" thread.

What is the maximum operating pressure and temperature of the tank?

The tank is designed for a maximum operating pressure of 3 bar and a maximum operating temperature of 95 °C, which provides a safe margin compared to typical operating temperatures of heating water of 60-80 °C.

What are the exact dimensions and weight of the tank?

Approximately, the diameter with insulation is about 1600 mm, the height is about 2450 mm and the weight of the empty tank is about 250 kg. These are estimated values corresponding to a volume of 3000 l - we recommend checking the exact dimensions with the seller before installation in confined spaces.

What is the warranty period on the buffer tank?

We provide a 24-month warranty on ATTACK buffer tanks from commissioning, but no more than 30 months from the date of dispatch from the factory.

Warranty and final recommendation

For the ATTACK Buffer Tank AK 3000 (insulation included in price), the manufacturer ATTACK s.r.o. provides a standard warranty of 24 months from commissioning, but no more than 30 months from the date of dispatch from the manufacturing plant. To maintain the warranty, we recommend connecting and commissioning the tank in accordance with the installation manual and applicable heating technology standards, using treated heating water and regularly checking the condition of the insulation and the tightness of the connection fittings. When choosing the right tank volume, we are happy to advise by phone or e-mail - just provide the type and output of your heat source and we will recommend the most suitable model from the ATTACK range.

Additional parameters

Category: Tanks without a heat exchanger
Weight: 250 kg
Tank volume: 3000 l
Tank type: Buffer (accumulation) tank without heat exchanger
Tank diameter (without insulation): 1400 mm (estimate)
Tank diameter (with insulation): 1600 mm (estimate)
Tank height: 2450 mm (estimate)
Weight of empty tank: 250 kg (estimate)
Tank material: Steel, internal coating / corrosion-resistant surface treatment
Insulation: Soft, removable, polyester filling, 100 mm thick
Outer cover of insulation: Leatherette (PVC fabric)
Insulation colour: silver-grey
Number of connection fittings: 6 pcs
Max. operating pressure: 3 bar
Max. operating temperature: 95 °C
Recommended heat source output: 120 - 150 kW
Country of origin: Slovakia
Manufacturer: ATTACK s.r.o.
Warranty: 24 months from commissioning, max. 30 months from dispatch

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field

About the company 

The product ATTACK is manufactured using the most modern production technologies available to us. As the most significant Slovak manufacturer of heating technology with purely Slovak capital and a single owner, we fully understand that each production process is reflected in the lifespan of this product and, of course, in your satisfaction. Therefore, we use only the best – from special boiler sheet metal through precise laser cutting of materials, to the most important – waterproof welds, which we perform exclusively robotically in precise fixtures, thus eliminating the human factor. All ATTACK products are high-quality premium products made using the most modern technology based on the latest research. The products have quality certificates from renowned testing laboratories and meet the conditions for the allocation of state subsidies. 

History of the company ATTACK

The production site of the company is located in the northern part of central Slovakia, about 20 km from the city of Žilina. Our company, which is engaged in the production of heating technology, started production in 1995 with stationary boilers and gradually expanded its production to today's level, where it produces a wide range of wall-mounted condensing boilers, stationary boilers, solid fuel boilers and TÚV tanks. The company ranks among medium-sized companies covering an area of approximately 5000 m2 covered area and about 1000 m2 uncovered area. Boiler production takes place in our own production halls and has its own development, design, sales and export to foreign markets.

Company profile and vision

“The main goal and philosophy of the company is to develop top products with the highest quality, functionality and design, which achieve the highest combustion efficiency with regard to the environment while maintaining a favorable price.“

The company ATTACK and product portfolio

We offer a wide selection of products that differ by type of fuel and power. All boilers are equipped with components from world manufacturers produced by the most modern technology, production controlled by camera and computer systems and tested by the most progressive devices and methods. In each group there is a wide range of choices both in modifications and in power. Boilers are mainly intended for heating of family houses, apartments and also larger businesses. The company profile includes a portfolio containing boilers for biomass, gas, electricity and accessories. In the production of boilers we use renewable energy source and that is photovoltaic panels with a power of 200kWp, which provide sufficient electrical energy for production.

Export and service

The company ATTACK exports its products to more than 51 countries around the world. Currently we export our products to all EU countries, Russia, USA, Canada and New Zealand. The biggest interest abroad is in modern wood gasifying and pellet and combined boilers, which are currently very popular in Europe and on the American continent as well as in stationary gas boilers, which reliably represent us even in distant Siberia.

A special approach to each customer, accommodating negotiations and reliability quickly grow into mutual trust, which ensures us a constant growth of customers in other countries.

Our service partners are trained in our own training center, which is equipped with products involved in real operation. Our partners are trained in two phases – theoretical and practical – where they have the opportunity to apply the theoretical part into practice and try everything on the products.The company ATTACK, s.r.o. covers the service network throughout the territory of Slovakia. In case of a breakdown, we can help you with up to 705 service organizations, whose professionally trained service technicians can quickly resolve any problem with an ATTACK product for heating of family houses, apartments or businesses.

Company profile – Research and development

The company ATTACK, s.r.o. has its own research and development center, where development and technical staff of the company annually innovate and prepare new heating technology devices. Emphasis is placed on the simplicity of device operation, modern design, environmental tolerance and minimal dimensions. All products are designed and developed in accordance with the relevant standards, specifications, legal and other regulations. The selection of components for ATTACK products is subject to the strictest criteria and only reliable and long-term operation verified components and materials from renowned suppliers can be used.

In development, ATTACK, s.r.o. does not cooperate with other manufacturers, but strives to always be one step ahead of the competition.

The company ATTACK – Certificates and awards

The company ATTACK, s.r.o. is the holder of the quality certificate ISO 9001:

  • for the design and development of boilers,
  • for the production of boilers,
  • service of devices and boilers

We place high emphasis on the quality of our products. We are the holders of the quality management certificate ISO 9001 since 2003. This quality certificate of international directive certifies activities in research and development, production, design and operation of gas equipment. The approval certificate was approved and issued by the prestigious London-based auditing company Lloyd’s Register Quality Assurance.

The demanding requirements placed on the company are also evidenced by the need to defend the certificate from the certification company LRQA every 3 years.

This quality management system indicates the progressiveness and positive approach of the company ATTACK, s.r.o. to the customer, to whom it proves its quality of a purely Slovak traditional company. The management system also emphasizes the company's strategy, which leads to its compliance, further development and improvement. All ATTACK® products are high-quality premium products made using the most modern technology based on the latest research. The products have CE, TÜV, GOST certificates from renowned testing laboratories around the world.

We regularly participate in domestic and foreign exhibitions of heating technology, where the company has received a whole range of awards from honorable mentions to gold medals.

Vytvořil Shoptet | Design Shoptak.cz.