ATTACK Spare part - pump RS 25/6, 130 mm
Code: OT01AProduct detailed description
ATTACK Replacement Part - Pump RS 25/6, 130 mm
Replacement circulation pump RS 25/6 with an installation length of 130 mm, electronically controlled, energy class A. A compact and affordable replacement part suitable for service replacements on boilers and pipework with a shorter distance between connections, including selected ATTACK models.
Just like the 180 mm variant (OT01), this is primarily an economical service replacement intended for post-warranty replacements and modernization of older, unregulated pumps, not an exclusive OEM part tied to a specific boiler production line.
Why choose a class A circulation pump
The circulation pump is one of the heating system components with the longest operating time – it runs practically non-stop during the season, which is why its efficiency is crucial for the overall operating economy of the boiler. This pump achieves an EEI index ≤ 0.20, placing it among the most economical solutions on the market for domestic and smaller commercial heating circuits.
Electronic control with automatic power adaptation (so-called auto-adapt or proportional pressure) continuously monitors the current state of the circuit – closing of thermostatic heads, flow changes with zone control – and adjusts the impeller speed accordingly. As a result, the pump does not run needlessly "at full throttle" when the system does not require it, which directly translates into savings on your electricity bill.
Compared to a standard unregulated pump of an older generation (for example, a classic three-speed type with a power input of 40 – 90 W at the highest setting), this class A pump can consume, at the same output, only 3 – 20 W at the average operating point, representing a noticeable saving over an entire heating season without any compromise in heating comfort.
How to choose the correct installation length – 130 mm or 180 mm
For circulation pumps, the "installation" or "construction" length refers to the distance between the axes of the pump's two connection ports. This value is not a matter of choice based on output, but must exactly match the existing spacing of the connections in the boiler or in the distribution pipework – it is therefore a purely dimensional, not a performance, parameter.
The most reliable procedure when choosing a replacement is to remove the original pump and physically measure the distance between the centers of its two connection ports using calipers or a tape measure. If the pump has not yet been removed, the dimension can also be verified from the type designation on the label (manufacturers commonly state the length directly in the model designation, for example as "-130" or "-180" at the end of the type code).
For service work on ATTACK boilers, we recommend always stating the exact production (serial) number of the boiler before ordering – this makes it possible to clearly verify which installation length and which exact pump type was factory-fitted in that particular boiler, since component suppliers may have changed during production runs even within the same boiler power range.
The connection threads of both length variants are standardized to a 1½" internal thread with a union nut, so in terms of the connection to the pipework itself there is no difference between the 130 mm and 180 mm versions – the only difference is the distance between the two ports.
Compact and affordable service replacement
The RS 25/6 in the 130 mm version is intended primarily for:
- post-warranty replacement of a faulty or unregulated pump with the same 130 mm installation length,
- modernizing an older installation to an electronically controlled class A solution with limited installation space,
- service work where price plays a decisive role while maintaining full functionality and energy class A,
- more compact boilers and manifolds with a shorter distance between connections, including some ATTACK models.
Unlike the -3-PR variant (OT01, 180 mm), this 130 mm RS 25/6 type is supplied in a basic version without an extended choice of operating curves, which is also reflected in its lower purchase price – hydraulically and energetically, however, both types remain very close to each other.
Technical parameters
- Installation length: 130 mm
- Energy class: A (EEI ≤ 0.20)
- Power input: 3 – 45 W, automatic control
- Maximum head: 6 m
- Maximum flow rate: up to 3.5 m³/h
- Connection: 1½" internal thread, union nut
- Medium temperature range: 2 – 110 °C
- Power supply: 230 V / 50 Hz, IP44 protection rating
How to read the circulation pump type label
The type label is attached directly to the body of the pump's electronic head and contains all the information needed to unambiguously identify it when ordering a replacement. In addition to the manufacturer's type designation (e.g. RS 25/6, Yonos PARA RS25/6), you will also find the installation length there (often directly in the number after the slash or in a note under the type), the supply voltage range, maximum power input, IP protection rating, and the serial/production number of the specific unit.
If the label is already illegible (for example, after years of operation in a humid boiler room environment), the most reliable option is to directly measure the installation length with calipers or contact our customer service with the production number of the ATTACK boiler itself – from this we can determine which pump was factory-fitted in that particular boiler.
When it is time to replace the circulation pump
The circulation pump is one of the components that usually does not fail suddenly, but whose performance and reliability gradually deteriorate with years of operation. Here are several symptoms to watch out for:
- Uneven heating – some radiators or circuits are noticeably colder than others, even with the thermostatic heads fully open, which may indicate insufficient pump delivery capacity.
- Increased noise – humming, squeaking or knocking during operation that does not disappear even after thoroughly bleeding the circuit usually indicates worn bearings.
- Frequent tripping of the thermal protection or outages – may indicate mechanical seizure of the rotor or an electrical fault in the motor winding.
- Visible leakage at joints or around the shaft – after years of operation, the seal or gasket may become worn.
- High electricity consumption compared to the declared values – an older unregulated pump without class A may consume several times more energy than a modern electronically controlled solution.
If any of these symptoms occur, we recommend replacing the pump before it fails completely, which could cause the boiler to overheat or the heating to fail at the most inconvenient moment of the heating season.
Installation – practical procedure
Replacing or installing a circulation pump is not complicated in itself, but requires following a few principles that affect the pump's service life and the trouble-free operation of the entire heating circuit:
- Shutting down and draining the circuit. Before removing the old pump or installing the new one, close the ball/shut-off valves on both sides of the pump (if fitted) and drain the water from that section of the circuit to minimize the leakage of medium and contamination of the boiler room.
- Checking the flow direction. The pump body has an arrow indicating the flow direction – the pump must be installed exactly in the direction of the heating water flow, otherwise it will not work efficiently or at all.
- Orientation of the motor head. After installation, the pump's electronic head (terminal box and control panel) must be oriented horizontally, never facing downward – this prevents condensate or any water leakage from entering the electronics. On horizontal pipework, the head is usually rotated into a side position.
- New gaskets. Use new flat gaskets under the union nuts with every pump replacement – worn original gaskets are the most common cause of microscopic leaks after servicing.
- Filling and bleeding. After screwing and tightening the joints, slowly fill the circuit with water with the shut-off valves open and bleed the system through the bleed valves at the highest points of the system as well as through any bleed screw at the front of the pump rotor (if included in the design).
- Checking tightness and function. After starting the boiler and the pump running up, check the tightness of both connections, the absence of unusual noise (humming may indicate air in the pump) and the correct function of the automatic power control when the heat load changes.
Always leave the electrical connection to a suitably qualified person (electrician or service technician) – the pump connects to a 230 V mains supply and, in boiler applications, may be powered directly from the boiler's control electronics.
Maintenance and extending the pump's service life
Electronically controlled circulation pumps in this category are practically maintenance-free – they contain no lubrication points or parts requiring regular servicing beyond a routine check. Nevertheless, a few simple habits will significantly extend their service life and maintain the declared energy class A throughout the operating period:
- Heating water quality. Excessive sludge, rust or air in the heating circuit is the most common cause of premature wear of the impeller and bearings of the wet-rotor motor. For older or recently distributed systems, we recommend considering the installation of a dirt filter or sludge separator upstream of the pump.
- Regular visual inspection. Once per heating season, check the tightness of the connections, the absence of corrosion marks on the pump body, and any unusual sounds (humming, knocking) that may indicate air in the system or an incipient bearing fault.
- Short-term shutdown outside the season. If the pump is not operating for a long period (e.g. outside the heating season in systems without year-round circulation), it is recommended to run it briefly from time to time to prevent the rotor from "seizing" due to deposits after prolonged inactivity – most modern pumps handle this automatically via a built-in permanent self-test.
- Frost protection. In unheated spaces (e.g. closed-down cottages, unheated technical rooms), where there is a risk of frost, either ensure the circuit is drained or use an antifreeze mixture with declared compatibility with the pump's materials.
Safety notices
Before any intervention on the pump, always disconnect the 230 V power supply and wait until the pump body has sufficiently cooled – heating water can reach temperatures close to 90 °C and there is a risk of burns. Electrical connection may only be carried out by a person with the appropriate electrical qualification in accordance with applicable standards (STN 33 2000 and related). The pump is not intended for operation outside the declared medium temperature and pressure range stated in the technical parameters – exceeding these limits may damage the pump and endanger operating safety.
Frequently asked questions
Is this part a full replacement for the OEM WILO Yonos PARA 130 mm (OT130A)?
Hydraulically and energetically, yes (same class A, head and flow rate), however it is an alternative, not an identical OEM part. For warranty service requiring the original part, we recommend the OT130A instead.
What is the difference compared to the 180 mm OT01 variant?
The main difference is in the installation length (130 mm compared to 180 mm) and in the fact that the OT01 (180 mm) additionally offers optional operating curves (-3 in the designation), whereas this 130 mm type comes in a basic version.
How exactly do I measure whether I need the 130 mm or 180 mm length?
Measure the distance between the centers of both connection ports of the original pump with calipers or a tape measure, or check the type designation on the label of the original pump, where the length is usually part of the code.
Is the pump suitable for a circuit with multiple zones controlled by thermostatic heads?
Yes, the electronic control automatically responds to flow changes caused by the closing of thermostatic heads and smoothly adjusts the output, preventing unnecessary noise in the fittings.
Is the pump supplied with installation accessories?
Yes, the package includes the union nuts and gaskets needed for standard installation on the 1½" thread.
What is the typical electricity consumption of this pump in normal operation?
Thanks to automatic control, the actual power input at the average operating point is usually in the range of a few watts up to a maximum of 45 W under the highest load, which is significantly less than with older unregulated pumps.
Can I adjust the pump's output setting myself without a service technician?
The basic operating mode setting can be made directly on the pump's control panel according to the enclosed instructions, however, if in doubt, we recommend calling in a heating technician, especially with more complex zone systems.
Is this part also suitable for other boiler brands, not just ATTACK?
Yes, it is a universal replacement part with a standard 1½" connection and a common 130 mm installation length, usable for most installations with the same connection spacing.
What should I do if the pump vibrates noisily after replacement?
Check that the union nuts are evenly tightened without stressing the pipework, that the circuit has been thoroughly bled, and that the pump has not been installed against the flow direction indicated by the arrow on the body.
Overview of related circulation pumps in the ATTACK range
When choosing a replacement pump with a 130 mm installation length, the ATTACK range offers several variants to choose from:
- ATTACK Pump WILO Yonos PARA RS25/6, 130 mm – original OEM part recommended for warranty service of ATTACK boilers.
- ATTACK Heating circulation pump 25/6, 130 mm, class A – universal pump also suitable for other boiler brands.
- ATTACK Replacement Part - Pump RS 25/6-3-PR, 180 mm – same product line, longer 180 mm variant with optional operating curves.
Summary
The ATTACK Replacement Part - Pump RS 25/6, 130 mm is a compact and affordable class A service replacement, suitable for installations with a shorter distance between connections, including selected ATTACK boiler models.
Warranty and support
We provide a 24-month warranty from the date of dispatch from the warehouse for this product. The warranty covers manufacturing and material defects provided the installation and operating conditions stated in the enclosed manufacturer's manual are observed. If you have any questions about selecting, compatibility, or installing the pump, please do not hesitate to contact our customer service – we will be happy to help identify the correct type based on the production number of your ATTACK boiler or the parameters of your heating circuit.
We recommend keeping the proof of purchase and, in case of servicing an ATTACK boiler, stating the type designation and production number of the boiler – this will speed up any warranty claims and future identification of replacement parts.
Additional parameters
| Category: | Attack |
|---|---|
| Weight: | 1.55 kg |
| Electrical class / EEI: | Class A, EEI ≤ 0.20 |
| Power input: | 3 – 45 W (automatic control based on load) |
| Supply voltage: | 230 V / 50 Hz |
| Maximum head: | 6 m |
| Maximum flow rate: | up to 3.5 m³/h |
| Connection thread: | 1½" (internal, union nut) |
| Medium temperature: | 2 °C to 110 °C |
| Protection rating: | IP44 |
| Pump body material: | cast iron / brass (wet-rotor construction) |
| Country of origin: | Slovakia (assembly), EU components |
| Manufacturer: | ATTACK s.r.o. |
| Warranty: | 24 months from dispatch |
| Installation length: | 130 mm |
| Type: | Replacement part - RS 25/6 (basic version) |
| Compatibility with ATTACK models: | boilers and manifolds with 130 mm connection spacing (verify by production number) |
Product rating
Be the first who will post an article to this item!
Discussion
List of discussions
About the company
The product ATTACK is manufactured using the most modern production technologies available to us. As the most significant Slovak manufacturer of heating technology with purely Slovak capital and a single owner, we fully understand that each production process is reflected in the lifespan of this product and, of course, in your satisfaction. Therefore, we use only the best – from special boiler sheet metal through precise laser cutting of materials, to the most important – waterproof welds, which we perform exclusively robotically in precise fixtures, thus eliminating the human factor. All ATTACK products are high-quality premium products made using the most modern technology based on the latest research. The products have quality certificates from renowned testing laboratories and meet the conditions for the allocation of state subsidies.
History of the company ATTACK
The production site of the company is located in the northern part of central Slovakia, about 20 km from the city of Žilina. Our company, which is engaged in the production of heating technology, started production in 1995 with stationary boilers and gradually expanded its production to today's level, where it produces a wide range of wall-mounted condensing boilers, stationary boilers, solid fuel boilers and TÚV tanks. The company ranks among medium-sized companies covering an area of approximately 5000 m2 covered area and about 1000 m2 uncovered area. Boiler production takes place in our own production halls and has its own development, design, sales and export to foreign markets.
Company profile and vision
“The main goal and philosophy of the company is to develop top products with the highest quality, functionality and design, which achieve the highest combustion efficiency with regard to the environment while maintaining a favorable price.“
The company ATTACK and product portfolio
We offer a wide selection of products that differ by type of fuel and power. All boilers are equipped with components from world manufacturers produced by the most modern technology, production controlled by camera and computer systems and tested by the most progressive devices and methods. In each group there is a wide range of choices both in modifications and in power. Boilers are mainly intended for heating of family houses, apartments and also larger businesses. The company profile includes a portfolio containing boilers for biomass, gas, electricity and accessories. In the production of boilers we use renewable energy source and that is photovoltaic panels with a power of 200kWp, which provide sufficient electrical energy for production.
Export and service
The company ATTACK exports its products to more than 51 countries around the world. Currently we export our products to all EU countries, Russia, USA, Canada and New Zealand. The biggest interest abroad is in modern wood gasifying and pellet and combined boilers, which are currently very popular in Europe and on the American continent as well as in stationary gas boilers, which reliably represent us even in distant Siberia.
A special approach to each customer, accommodating negotiations and reliability quickly grow into mutual trust, which ensures us a constant growth of customers in other countries.
Our service partners are trained in our own training center, which is equipped with products involved in real operation. Our partners are trained in two phases – theoretical and practical – where they have the opportunity to apply the theoretical part into practice and try everything on the products.The company ATTACK, s.r.o. covers the service network throughout the territory of Slovakia. In case of a breakdown, we can help you with up to 705 service organizations, whose professionally trained service technicians can quickly resolve any problem with an ATTACK product for heating of family houses, apartments or businesses.
Company profile – Research and development
The company ATTACK, s.r.o. has its own research and development center, where development and technical staff of the company annually innovate and prepare new heating technology devices. Emphasis is placed on the simplicity of device operation, modern design, environmental tolerance and minimal dimensions. All products are designed and developed in accordance with the relevant standards, specifications, legal and other regulations. The selection of components for ATTACK products is subject to the strictest criteria and only reliable and long-term operation verified components and materials from renowned suppliers can be used.
In development, ATTACK, s.r.o. does not cooperate with other manufacturers, but strives to always be one step ahead of the competition.
The company ATTACK – Certificates and awards
The company ATTACK, s.r.o. is the holder of the quality certificate ISO 9001:
- for the design and development of boilers,
- for the production of boilers,
- service of devices and boilers
We place high emphasis on the quality of our products. We are the holders of the quality management certificate ISO 9001 since 2003. This quality certificate of international directive certifies activities in research and development, production, design and operation of gas equipment. The approval certificate was approved and issued by the prestigious London-based auditing company Lloyd’s Register Quality Assurance.
The demanding requirements placed on the company are also evidenced by the need to defend the certificate from the certification company LRQA every 3 years.
This quality management system indicates the progressiveness and positive approach of the company ATTACK, s.r.o. to the customer, to whom it proves its quality of a purely Slovak traditional company. The management system also emphasizes the company's strategy, which leads to its compliance, further development and improvement. All ATTACK® products are high-quality premium products made using the most modern technology based on the latest research. The products have CE, TÜV, GOST certificates from renowned testing laboratories around the world.
We regularly participate in domestic and foreign exhibitions of heating technology, where the company has received a whole range of awards from honorable mentions to gold medals.
