Flue gas retarder for the lower flue gas chamber, 500mm

Code: S0427
Not rated Rating details
110,71 € / pcs 90,01 € excl. VAT Measure price:
International delivery
In stock at supplier

Detailed information

Product detailed description

Flue gas retarder S0427, length 500 mm

The code S0427 designates a retarder that is fitted in the lower part of the flue gas chamber of an ATMOS boiler. It is supplied in a length of 500 mm and in the e-shop you will find it among the other spare parts.

DetailValue
Part codeS0427
Length500 mm
Locationlower flue gas chamber
Categoryother spare parts

Intended for ATMOS boilers

  • SX series: DC30SX, DC40SX
  • SE series: DC40SE

Before ordering, please check the exact designation of your boiler and compare it with the list of types above.

Frequently asked questions

  • How do I choose the right output for a solid-fuel boiler? Start from the calculated heat loss of the heated building, but with wood/coal boilers also bear in mind that during a single load the boiler burns for several hours at essentially constant output - which is why it is common practice to add a buffer (accumulation) tank, which stores the excess heat for later use instead of the boiler having to be throttled down inefficiently.
  • What else do I need to install this boiler? Besides the boiler itself, the system usually requires: a buffer (accumulation) tank of suitable volume, a circulation pump (often with a built-in Laddomat or a thermoregulating valve to protect the boiler against low-temperature corrosion), a safety valve, an expansion vessel and a flue/chimney with sufficient draught matching the boiler output - the exact chimney draught values can be found in the technical parameters above.
  • What fuel is suitable and what is not? Use only the fuel recommended by the manufacturer for the given model (usually split logs of a defined length and moisture content, or brown-coal briquettes or coal, depending on the boiler type) - unsuitable or too moist fuel reduces efficiency, increases the formation of tar and deposits and can damage the boiler.
  • What about the chimney inspection and legal requirements? Before the boiler is put into operation, and also regularly during its use (usually once a year for solid fuels), an inspection/cleaning of the chimney by an authorised chimney sweep is required by law - without the relevant inspection certificate, an insurance claim in the event of a fire may also be disputed.
  • How much maintenance does the boiler need? It normally includes regular removal of ash and cleaning of the heating surfaces/flue gas passages of soot (the interval depends on the intensity of use, usually in the order of weeks), and a thorough annual inspection including the seals and the chimney.
  • Can I install the boiler myself? The positioning and connection of the boiler to the heating system, the chimney and the safety components should be carried out, or at least professionally checked, by a heating engineer - it is an appliance with an open fire, high temperatures and pressurised components, where a connection error can be a safety risk.

Additional parameters

Category: other spare parts
Warranty: 2 years
Weight: 2.369 kg

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field

Company History

The family company ATMOS was founded in the Czech Republic in 1935. In the beginning, production was focused on gasifier power units for cars and boats under the brand name DOKOGEN, i.e. the same principle used in modern gasifier boilers for wood and coal.

 
 
 

Despite the German occupation and communist dictatorship, it was possible to maintain the development of wood boilers, gasifier units and compressors. In 1980, at the Pragotherm exhibition, the first wood gasifier boilers and wood waste boilers were presented. To date, 90 types of hot water boilers have been developed, for which the company holds 15 patents. One of the first developed boilers was the EKONOMIK boiler in 1968.

 

 

To ensure the European market with quality boilers that save the environment and energy, three generations of the Cankář family are currently working in the family business. The founder of the company, Jaroslav Cankář senior, passed away in March 2006 at the age of 94.

Company ATMOS – present

Atmos is a Czech family company and currently one of the largest European manufacturers of solid fuel boilers. The company exports more than 60% of its production abroad, mainly to Germany, Austria, Sweden, Italy, France, Romania, Poland, Bulgaria, Denmark, Slovakia, Lithuania, Latvia, Ukraine, Belarus, Spain, the United Kingdom, etc.

 

The product range includes solid fuel boilers, gasification boilers for wood from 15 to 150 kW, gasification boilers for brown coal (and wood) from 16 to 48 kW, gasification boiler for brown coal briquettes and black coal with a power of 16 and 26 kW, automatic pellet boilers from 4.5 to 80 kW and combined boilers for gasification of wood in combination with a pellet burner in power from 20 to 35 kW. Products of the company Atmos have aroused great interest among users heating with wood and installers, due to their good functionality, quality and, last but not least, very favorable price.

The goal of the company ATMOS is to be one of the best boiler manufacturers in Europe. To be a company that values its tradition, experience and the ATMOS brand

Vytvořil Shoptet | Design Shoptak.cz.