DAB GRINDER FX 15.11 M-NA – submersible sewage pump with cutter, 1x230 V, without float switch
Code: 60191240Product detailed description
DAB GRINDER FX 15.11 M-NA is a submersible sewage pump with a cutting system for pumping wastewater from sewers in residential and commercial settings, including water containing fibres, paper or textile material.
Key features
- Certified to EN 12050-1; thanks to the cutting system the pump is also suitable for small-diameter piping.
- The pump body and impeller are cast iron, the cutting system is AISI 630 stainless steel; the double SiC-SiC / SiC-C mechanical seal runs in an oil chamber.
- Continuous S1 duty is possible with the motor fully submerged; dry running is permitted for 10 minutes at most, and the winding overheat sensors trip at +130 °C.
- The outlet is available with a flange or a thread (from 1 1/2", DN 32, DN 40); protection IP68, insulation class F.
- The FX 15 series handles a flow of up to 23.8 m³/h at a head of up to 33 m; liquid up to +50 °C (+60 °C for short periods), maximum immersion depth 20 m.
- Installation is portable on a base at the bottom of the tank or fixed with a lifting device; the design gives quick access to the main components for maintenance.
This version
Designation GRINDER FX 15.11 M-NA: single-phase motor 1x230 V, without float switch. In the GRINDER FX series M means a single-phase and T a three-phase motor, A a float switch for automatic operation and NA a version without float.
Electrical connection and commissioning should be carried out by a qualified person.
Technical data
| Code | 60191240 |
| Manufacturer | DAB |
| Type | DAB GRINDER FX 15.11 M-NA |
| Supply | 1x230 V, 50 Hz |
| Float switch | no |
| Standard | EN 12050-1 |
| Outlet connection | flange or thread, from 1 1/2" (DN 32, DN 40) |
| Max. immersion depth | 20 m |
| Liquid temperature | up to +50 °C (+60 °C for short periods) |
| Protection / insulation | IP68 / F |
| Supply cable | 10 m H07RN8-F |
| Max. dry running | 10 min |
Frequently asked questions
What do the designations M-A, M-NA and T-NA mean?
M is a single-phase and T a three-phase motor. A means a float switch for automatic switching, NA a version without float.
What is the cutting system for?
It chops fibres, paper and textiles in the wastewater, so the pump can be connected to small-diameter piping.
How long can the pump run dry?
10 minutes at most. The manufacturer states continuous S1 duty with the motor fully submerged.
Additional parameters
| Category: | DAB.GRINDER FX - sewage pump with grinder |
|---|---|
| Warranty: | 2 years |
| Code: | 60191240 |
| Manufacturer: | DAB |
| Type: | DAB GRINDER FX 15.11 M-NA |
| Supply: | 1x230 V, 50 Hz |
| Float switch: | no |
| Standard: | EN 12050-1 |
| Outlet connection: | flange or thread, from 1 1/2" (DN 32, DN 40) |
| Max. immersion depth: | 20 m |
| Liquid temperature: | up to +50 °C (+60 °C for short periods) |
| Protection / insulation: | IP68 / F |
| Supply cable: | 10 m H07RN8-F |
| Max. dry running: | 10 min |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!