DAB.EVOPLUS B 120/220.32 M flanged circulation pump with electronic control for heating and air conditioning, DN 32
Code: 60150962Product detailed description
DAB.EVOPLUS B 120/220.32 M (code 60150962) is a wet rotor circulation pump with a synchronous motor with permanent magnets, whose speed is controlled by a frequency converter. It belongs to the EVOPLUS range intended for larger heating, ventilation and air conditioning systems – apartments, single-family homes, schools, hospitals or administrative buildings. This model has a simple flanged version with a single-phase motor, DN 32 connection and a construction length of 220 mm.
Performance of the EVOPLUS B 120/220.32 M model
The pump achieves a pumping head of up to 12 m and a flow rate of up to 17.01 m³/h, with a maximum power P1 of 340 W. With an energy efficiency index EEI ≤ 0.22, it complies with the ErP 2009/125/ES directive. The electronics continuously evaluates changes in the system hydraulics, for example when opening and closing individual branches, and adjusts the speed accordingly – the circuit receives the required flow without unnecessary energy consumption.
Control and connection to the control system
- proportional (Δp-v) or constant (Δp-c) differential pressure, constant curve and regulation depending on the liquid temperature
- economical function and remote switching on and off
- inputs for an analogue signal 0–10 V or 4–20 mA, PWM signal and temperature sensor, output for fault indication
- ModBus communication, LonBus with an additional module
- OLED display and three buttons on the control panel
Construction
The pump body is made of cast iron, the impeller is made of technopolymer and the stainless steel shaft rotates in ceramic bearings lubricated by the pumped liquid; the motor housing is made of pressure-cast aluminium. The suction and discharge nozzles have threaded connections for pressure and temperature measurement. Thermal insulation of the body is part of the delivery – it reduces heat losses and condensation formation, so the pump can also handle cooling circuits with liquid colder than the environment. The motor does not require external protection: the electronics protects it against overload, overheating, phase failure and overvoltage and undervoltage.
Installation and operating conditions
The pump must always be installed with the motor shaft in a horizontal position, the control electronics must be in a vertical position and must not be insulated. The pumped liquid must be clean, without solid particles and mineral oils, with a glycol content of up to 30 % and a temperature from −10 to +110 °C; the ambient temperature must be up to 40 °C. The maximum operating pressure is 16 bar and at least 10 m of water column must be maintained on the suction side at 90 °C, or 20 m of water column at 110 °C. Flanges DN 32 PN 6 are not part of the packaging, they are supplied on request. The cast iron version is not intended for potable water. Electrical connection (1 × 220–240 V, 50/60 Hz) and commissioning must be carried out by a qualified person.
Technical parameters
| Code | 60150962 |
| Manufacturer | DAB |
| Type | DAB.EVOPLUS B 120/220.32 M |
| Version | simple flanged, single-phase motor |
| Connection | flanges DN 32 |
| Construction length | 220 mm |
| Max. pumping head | 12 m |
| Max. flow rate | 17.01 m³/h |
| Max. power P1 | 340 W |
| Energy efficiency index | EEI ≤ 0.22 |
| Power supply | 1 × 220–240 V, 50/60 Hz |
| Protection / insulation class | IP44 / F |
| Liquid temperature | −10 to +110 °C |
| Max. operating pressure | 16 bar |
| Weight | 14 kg |
Frequently asked questions
What does the designation EVOPLUS B 120/220.32 M mean?
B indicates a simple flanged version, 120 is the maximum pumping head in decimetres (12 m), 220 is the construction length in millimetres and 32 is the nominal flange diameter DN 32. The letter M means a single-phase motor 220–240 V.
Are the flanges part of the packaging?
No, flanges DN 32 PN 6 are supplied on request with the pump. The thermal insulation of the body is, however, part of the packaging.
Which Grundfos pump can be replaced by this model?
The comparison table in the IVAR technical sheet lists EVOPLUS B 120/220.32 M as equivalent to Grundfos MAGNA 32-120 F, MAGNA 1 32-120 F, MAGNA 3 32-120 F and UPS 32-120 F. Before replacement, check the construction length, flange and system operating point.
In which position is the pump installed?
Always so that the motor shaft is horizontal and the control electronics is vertical. Do not insulate the electronics and do not cover the condensation discharge openings.
Additional parameters
| Category: | DAB.EVOPLUS - electronic circulation pumps for larger heating/air conditioning |
|---|---|
| Warranty: | 2 years |
| Weight: | 14 kg |
| Availability: | In stock or at supplier |
| Code: | 60150962 |
| Manufacturer: | DAB |
| Type: | DAB.EVOPLUS B 120/220.32 M |
| Version: | single flanged, single-phase motor |
| Connection: | DN 32 flanges |
| Installation length: | 220 mm |
| Max. head: | 12 m |
| Max. flow: | 17.01 m³/h |
| Max. power input P1: | 340 W |
| Energy efficiency index: | EEI ≤ 0.22 |
| Power supply: | 1 × 220–240 V, 50/60 Hz |
| Protection rating / insulation class: | IP44 / F |
| Fluid temperature: | −10 to +110 °C |
| Max. operating pressure: | 16 bar |
| Weight: | 14 kg |