Ground/water heat pump THERMIA CALIBRA E COOL 12 (BW) with cooling – 3–12 kW, up to 65 °C, 184 l HW – SPECIAL OFFER
Code: IHP206944Product detailed description
THERMIA CALIBRA E COOL 12 (code IHP206944) is a compact inverter heat pump ground/water, which in addition to heating and hot water preparation can also cool the house in summer. It extracts heat from a borehole or a flat ground collector and operates in the range of 3–12 kW. The CALIBRA E range is suitable for new buildings and renovations with a heat loss up to 24 kW.
Main features
- inverter-controlled scroll compressor Copeland and variable speed circulation pumps – power is smoothly adjusted to the house's needs in the range of 3–12 kW
- water temperature at the outlet up to 65 °C, suitable for floor heating and radiators
- refrigerant R452B with GWP 698 (charge 1.3 kg), stainless steel plate heat exchangers
- SCOP 5.85 at 35 °C and 4.39 at 55 °C (EN 14825, cold climate); in average climate 5.67 / 4.25, COP 4.78 at B0/W35, energy class A+++
- built-in stainless steel hot water tank 184 l with TWS technology, water volume at 40 °C (V40) up to 260 l
- control system GENESIS with color touch display, built-in web server for Thermia Online, Modbus for building automation and Smart Grid function for photovoltaics
- anti-vibration flexible pipe built into the cabinet – external flexible hoses are not necessary
System expansion
The COOL model has cooling directly in the heat pump, so it does not need a separate passive cooling hydromodule; the cooling temperature is set in a separate Cooling menu. An activated buffer tank and active cooling are not available with this model. With the expansion card EM3 you can add a mixing circuit, an external auxiliary heat source and pool heating. Pipes used for cooling must be vapour-tight insulated.
Design and installation
Power is designed in the calculation program Thermia HPC. The heat pump is placed in a frost-free room on a solid base, ideally a concrete floor, and not in a corner – with a filled tank it weighs 359 kg. The antifreeze circuit is filled with a mixture of water and ethanol with a freezing point of -17 ± 2 °C, a magnetic dirt separator with a filter must be installed in the return of the heating system and there must be at least 14 l of water per kW of minimum power in the system. The connecting kit IVAR.TER-PS (IHP08645676) is ordered separately. Installation and commissioning is carried out by a professional company, electrical installation by an electrician and work on the cooling circuit by a technician qualified in refrigeration technology.
Technical parameters
| Code | IHP206944 |
| Manufacturer | THERMIA |
| Type | BW CALIBRA E COOL 12 |
| Type of heat pump | ground/water (BW), inverter |
| Power range | 3–12 kW |
| Max. outlet temperature | 65 °C |
| Refrigerant | R452B, 1.3 kg |
| COP (B0/W35) | 4.78 |
| SCOP 35 / 55 °C (cold climate) | 5.85 / 4.39 |
| Energy class 35 / 55 °C | A+++ / A+++ |
| Hot water tank | 184 l, stainless steel, TWS |
| Power supply | 400 V 3-N, 50 Hz |
| Auxiliary electric heating | (0)/3/6/9 kW |
| Dimensions (w × h × d) | 598 × 703 × 1863 mm |
| Weight | 169 kg (filled 359 kg) |
Frequently asked questions
For which house is the CALIBRA E COOL 12 heat pump suitable?
The model operates in the range of 3–12 kW with water temperature up to 65 °C, so it is suitable for floor heating and radiators in new buildings and renovations. The exact power is determined by a calculation in the Thermia HPC program according to the house's heat loss.
What is included in the delivery?
The heat pump is delivered with safety valves 9 and 3 bar, an external temperature sensor, an expansion vessel and a charging device for the antifreeze circuit and a dirt filter with a shut-off valve. The connecting kit IVAR.TER-PS (IHP08645676) is ordered separately.
How does the cooling work in the COOL version?
The cooling function is part of the heat pump and is set in a separate Cooling menu, without an external passive cooling hydromodule. Active cooling and an activated buffer tank are not available with this model.
Can the heat pump be controlled remotely?
Yes, the built-in web server allows control and monitoring via Thermia Online from a phone, tablet or computer. The Smart Grid function also enables cooperation with photovoltaics.
Additional parameters
| Category: | ground / water heat pumps |
|---|---|
| Warranty: | 2 years |
| Weight: | 169 kg |
| Availability: | In stock or at supplier |
| Code: | IHP206944 |
| Manufacturer: | THERMIA |
| Type: | BW CALIBRA E COOL 12 |
| Heat pump type: | brine-to-water (BW), inverter |
| Output range: | 3–12 kW |
| Max. flow temperature: | 65 °C |
| Refrigerant: | R452B, 1.3 kg |
| COP (B0/W35): | 4.78 |
| SCOP 35 / 55 °C (cold climate): | 5.85 / 4.39 |
| Energy class 35 / 55 °C: | A+++ / A+++ |
| DHW cylinder: | 184 l, stainless steel, TWS |
| Power supply: | 400 V 3-N, 50 Hz |
| Electric auxiliary heater: | (0)/3/6/9 kW |
| Dimensions (W × D × H): | 598 × 703 × 1863 mm |
| Weight: | 169 kg (filled 359 kg) |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!