Product detailed description

The IVAR.ST 30 AL board (code ST30AL) is a thermal insulation board for the dry system of hydronic floor heating. It is suitable wherever it is not possible or appropriate to use a concrete screed or self-leveling compound – for example in renovations where a screed would unnecessarily overload the structure, in wooden buildings sensitive to moisture, or in cases of low available structural height.

Board Features

  • thickness 30 mm, format and usable dimensions 1200 × 600 mm = 0.72 m²
  • for PE-RT 16 × 2 mm pipes with a laying distance of 150 mm
  • surface aluminum layer of 100–200 µm thickness distributes heat across the surface
  • EPS 300 insulation: thermal conductivity λD 0.0318 W/mK, thermal resistance RD 0.95 m²K/W
  • reaction to fire class E, in accordance with DIN EN 13163

Floor Composition

Gypsum fiber boards are laid on top of the board – the manufacturer recommends Fermacell or Knauf boards of 25 mm thickness, on which ceramic tiles can be glued. For laminate flooring, a 12.5 mm gypsum fiber board is sufficient. If the lowest possible construction height is required, the ST20AL board system allows a total structural height of 45 mm without the final floor covering. On a stable and load-bearing base, ceramic tiles can also be laid directly on the board. Compared to the 20 mm board, the ST30AL has a higher thermal resistance (0.95 vs. 0.65 m²K/W).

Technical Parameters

CodeST30AL
BrandIVAR
TypeIVAR.ST 30 AL
Systemdry system floor heating
Thickness30 mm
Format1200 × 600 mm
Usable area0.72 m²
Laying distance150 mm
PipesPE-RT 16 × 2 mm
InsulationEPS 300
Thermal conductivity λD0.0318 W/mK
Thermal resistance RD0.95 m²K/W
AL layer thickness100–200 µm
Reaction to fire classE

Frequently Asked Questions

Do I need a concrete screed with this board?
No. The board is designed for a dry system, in which gypsum fiber boards replace the screed – the manufacturer recommends Fermacell or Knauf boards of 25 mm thickness.

What kind of pipes are laid in the board?
PE-RT pipes with an external dimension of 16 × 2 mm with a laying distance of 150 mm.

What is the difference between ST20AL and ST30AL boards?
ST20AL has a thickness of 20 mm, EPS 400 insulation, and a thermal resistance of 0.65 m²K/W. ST30AL has a thickness of 30 mm, EPS 300 insulation, and a thermal resistance of 0.95 m²K/W.

Additional parameters

Category: IVAR INSULATION
Warranty: 2 years
Availability: In stock or at supplier
Code: ST30AL
Brand: IVAR
Type: IVAR.ST 30 AL
System: dry-system underfloor heating
Thickness: 30 mm
Format: 1200 × 600 mm
Usable area: 0.72 m²
Laying spacing: 150 mm
Pipes: PE-RT 16 × 2 mm
Insulation: EPS 300
Thermal conductivity λD: 0.0318 W/mK
Thermal resistance RD: 0.95 m²K/W
Aluminium layer thickness: 100–200 µm
Reaction to fire: class E

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field

IVAR designs, develops and manufactures highly energy-efficient heating and plumbing systems. We have over 10,000 catalogue items - mass-produced products and unique items - in addition to customised systems and combinations of complex products. And it’s all “Made in Italy”.

 

Vision
To make life easier for our clients, our clients' customers and our employees, thanks to our ability to be constantly innovative.

 

Mission
To design and manufacture advanced hydronic solutions that reduce installation complexity and energy consumption.

 

“Made in Italy” adds value

IVAR has been producing heating and plumbing system components since 1985: valves for heating bodies, direct heat metering modules, heat cost allocators, pipes and fittings, substations for heating systems, distribution manifolds, radiant panel systems, and components for solar and geothermal systems. And it’s all “Made in Italy”.
Over 200 people are employed at our manufacturing facilities in Prevalle (in northern Italy’s Brescia province). The site has been designed to streamline our many production and operational stages.

The Italian headquarters also acts as a hub for the wider IVAR Group, set up with the goal of distributing products beyond Italy’s borders. The group now has 11 branches, in Australia, Belgium, China, Germany, the United Kingdom, the Czech Republic, Romania, Slovakia, Spain, the United States and Tunisia.

 

Know How
Research, development and numerous laboratory tests guarantee that our clients’ requests can be translated into new high-efficiency products.

The stages required for production take place internally, beginning with hot forming, which is carried out at our subsidiary Valmon Stampati. Our continuous implementation of projects under the Industry 4.0 initiative also allows us to take full advantage of new releases in technology and IT to improve our manufacturing efficiency.


As a company, IVAR is constantly evolving. Every day, we invest in strengthening our products, in improving our production processes and in attaining new patents and certifications.

Vytvořil Shoptet | Design Shoptak.cz.