DAB.DRENAG FX 15.07 M-NA submersible dirty-water pump, single-phase without float
Code: 60191217Product detailed description
DAB.DRENAG FX 15.07 M-NA (code 60191217) is a submersible pump for draining slightly polluted ground and rain water in commercial buildings and sandy water on building sites. It suits applications that need a high head – the DRENAG FX series reaches up to 32 m head and up to 30.9 m³/h flow. The pump is certified to EN 12050-2 and passes solid particles up to 10 mm.
Version 15.07 M-NA
- single-phase motor with built-in capacitor, without float – switching is handled by a control panel with float switches
- IP68 protection, motor insulation class F, dry running for 10 minutes at most
Construction and installation
The open impeller and the wear-resistant rubber surface cope with water containing abrasive particles too. The double silicon carbide mechanical seal sits in an oil chamber outside the pumped liquid, and the cable gland with quick connector is potted in resin. The outlet is connected with a 1 1/2" thread or a DN 32 or DN 40 flange. The pump can be placed as a portable unit straight on the tank bottom or installed permanently with a lifting device, and its design gives quick access for maintenance. The liquid temperature may be up to +50 °C, briefly +60 °C.
Installation and electrical connection should be carried out by a qualified person.
Technical data
| Code | 60191217 |
| Manufacturer | DAB |
| Type | DAB.DRENAG FX 15.07 M-NA |
| Supply | single-phase |
| Float | no |
| Pumped liquid | slightly polluted ground, rain and sandy water |
| Solids passage | particles up to 10 mm |
| Impeller | open, with wear-resistant surface |
| Outlet connection | 1 1/2" / DN 32 / DN 40 |
| Protection / insulation | IP68 / F |
| Liquid temperature | up to +50 °C (briefly +60 °C) |
| Standard | EN 12050-2 |
Frequently asked questions
Does the pump have a float?
No, the NA version has no float. Switching must be arranged with a control panel connected to float switches or another level monitoring system.
Is the pump also suitable for sewage with faecal matter?
No, the DRENAG FX is intended for slightly polluted ground, rain and sandy water with particles up to 10 mm. For waste water with larger solids a different series is meant, for example FEKA FX or GRINDER FX.
How long may the pump run dry?
For 10 minutes at most. Longer dry running must be ruled out by setting the switch-off level correctly.
Additional parameters
| Category: | DAB.DRENAG FX - submersible sewage pump |
|---|---|
| Warranty: | 2 years |
| Code: | 60191217 |
| Manufacturer: | DAB |
| Type: | DAB.DRENAG FX 15.07 M-NA |
| Supply: | single-phase |
| Float: | no |
| Pumped liquid: | slightly polluted ground, rain and sandy water |
| Solids passage: | particles up to 10 mm |
| Impeller: | open, with wear-resistant surface |
| Outlet connection: | 1 1/2" / DN 32 / DN 40 |
| Protection / insulation: | IP68 / F |
| Liquid temperature: | up to +50 °C (briefly +60 °C) |
| Standard: | EN 12050-2 |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
