Protherm Puma Condens 18/24 MKV
Code: 0010026142Related products
Product detailed description
Protherm PUMA Condens 18/24 MKV
- wall-mounted condensing boiler with instantaneous hot water heating
- output: 6,0 - 18,3 kW
- A very cost-effective boiler for heating and hot water preparation
- Suitable for new buildings as well as for replacing older gas boilers
- Gas savings of up to 30% compared to old non-condensing boilers
- A quality product with proven components
- Simple yet intelligent operation via the boiler’s display
- Reliable and robust stainless-steel heat exchanger
- Easily removable condensate container for simple maintenance and cleaning
- Highly efficient pump with low electricity consumption
- 8 l expansion vessel
- Smooth output modulation
- Built-in self-diagnostics
- eBus communication interface
- One of the smallest and lightest condensing boilers in its class: width x height x depth: 400 x 626 x 270 mm, weight: 25 kg
- Quick and easy installation, especially thanks to its dimensions
| Puma Condens 18/24 MKV | |
| Heating | |
| Output at temperature gradient 50/30°C [kW] | 6,0 – 20,0 |
| Output at temperature gradient 75/55°C [kW] | 6,0 – 18,3 |
| Fuel | natural gas, propane |
| Adjustable heating flow temperature range [°C] | 30 – 75 |
| Max. working pressure [MPa] | 0,3 MPa (3,0 bar) |
| ErP heating class (A+++ - D) | A |
| Expansion vessel [l] | 8 |
| Hot water heating | |
| Maximum output for hot water preparation [kW] | 24 |
| Min. - Max. hot water inlet pressure [MPa] | 0,03 - 1 MPa (0,3 - 10 bar) |
| Adjustable hot water temperature range [°C] | 35 - 55 |
| Specific hot water flow rate at ΔT = 30 K [l/min] | 11,5 |
| Minimum hot water flow rate [l/min] | 1,7 |
| ErP water heating class (A+ - F) | A |
| Electrical parameters | |
| Voltage/frequency [V/Hz] | 230/50 |
| Power input in standby mode [W] | 90 (1,7) |
| Electrical protection rating [IP] | IPX5 |
| Dimensions | |
| Dimensions (width/height/depth) [mm] | 400/626/270 |
| Weight without water [kg] | 25 |
Frequently asked questions
- How exactly do I choose the right output for a PROTHERM condensing boiler? The starting point is the calculated heat loss of the heated building (most reliably taken from the project documentation or an energy certificate). If you don't have a project, you can estimate roughly 60-100 W per m² of floor area for a normally insulated house built after 2000, or 100-150 W/m² for an older, non-insulated house - the exact figure varies depending on the number of floors, ceiling height, the number and quality of windows, and the building's orientation. A boiler oversized for its output switches on and off more often (so-called cycling), which shortens its lifespan and reduces efficiency; an undersized boiler, on the other hand, cannot sufficiently heat the house on frosty days.
- Why is a condensing boiler more economical than a classic one? A condensing boiler also makes use of the heat hidden in the water vapour produced when gas is burned - in a classic boiler this heat escapes unused through the flue, while in a condensing boiler it is cooled below the so-called dew point, the vapour condenses, and the released heat is returned to the heating circuit. Thanks to this, condensing boilers reach an efficiency of approximately 105-110% relative to the calorific value of the gas, compared to the usual 85-92% for classic boilers.
- What type of flue gas exhaust does this boiler need? Most modern condensing boilers are so-called turbo boilers (with a sealed combustion chamber) and require a concentric (coaxial) or separate flue gas exhaust and combustion air supply routed through the outer wall or roof - so they do not need a functional chimney. You will find the exact type and maximum length of the exhaust (depending on the 60/100 or 80/125 mm diameter) in the technical documentation for the specific model, or you can consult our customer service.
- What does the ErP energy class stated for the boiler mean? This is a mandatory efficiency label for heating appliances under the EU ErP (Ecodesign) directive, similar to the energy labels on refrigerators. Condensing boilers commonly reach class A, or even higher in combination with room control (e.g. A+ when using weather-compensated control and a room thermostat).
- Can I install and connect this boiler myself? No. Connection to the natural gas supply, the electrical network and the flue gas exhaust is, by law, exclusively the job of a person with the relevant authorisation (most often an authorised service technician of the given brand or a gas appliance inspection technician). After installation, the boiler must be commissioned by the manufacturer's authorised service, which is usually also a condition for the warranty to be valid.
- What about servicing and the warranty? Most manufacturers require a regular annual service inspection by an authorised service provider in order for the warranty to remain valid even after its standard expiry (an extended warranty with regular servicing is common especially for the brands Vaillant, Protherm, Viessmann). You will find the exact warranty terms in the warranty certificate supplied with the boiler.
- What is included in the delivery of this specific product? The exact package contents (the boiler itself, possibly a hot water tank, room control and other accessories in the case of a set) are stated in the product name and in its technical parameters higher up on this page.
Additional parameters
| Category: | Protherms integrovaným zásobníkom vysoký výkon nad 16 kW Protherms prietokovým ohrevom vody vysoký výkon nad 16 kW Protherm |
|---|---|
| Warranty: | 2 years |
| Weight: | 28 kg |
| EAN: | 8586018277310 |
| Boiler intended use: | with an integrated storage tank, with flow-through hot water heating |
| Boiler heating output: | high output above 16 kW |
| Manufacturer: | Protherm |
| EAN: | 8586018277310 |
| Package dimensions (mm): | 454 x 741 x 320 |
Product rating
Leave a rating
List of ratings
Discussion
List of discussions
Listing controls
About the company
The company Protherm Production is part of the Vaillant Group and is a manufacturer of heating technology for many countries in Europe, Asia and Africa. For the Slovak market, it produces boilers of the Vaillant and Protherm brands. Protherm Production is not only a production plant. It also includes one of the most modern research and development centres, a testing centre and a distribution and logistics centre for Central and Eastern Europe.
The company's beginnings date back to 1991, when it operated as a seller of heating technology in Prague. Production in Skalica was initially launched in the company Didaktik, from where it was moved to the premises of the current plant in 1999. Since 2001, it has been part of the German Vaillant Group.
Three Slovak entities: The Vaillant Group employs more than 1,800 people in Slovakia. In addition to the plant in Skalica, it also owns the company Vaillant Industrial Slovakia in Trenčianske Stankovce, which produces hydraulic modules and pipes. The sales organisation for the Slovak market is the company Vaillant Group Slovakia, which also ensures further customer care and servicing of the products offered.
The Vaillant Group has a history of over 140 years and more than 2,000 patents. It is a leader and pioneer in the field of heating technologies in Europe. It has 10 production plants worldwide (eight in Europe, one in Turkey and one in China) and more than 12,000 employees. It produces equipment under the brands Vaillant, Protherm, Saunier Duval, Bulex, AWB, DemirDöküm, Glow-Worm and Hermann.