Thermia ITEC E-PLUS 12 (ITEC E-P 12) air-to-water heat pump – 3.4–12 kW, flow temperature up to 65 °C – SALE
Code: IHP203243PProduct detailed description
ITEC E-PLUS 12 (ITEC E-P 12) is a Thermia inverter heat pump from the IVAR.HP iTec E range for family houses and apartments – for new builds as well as renovated buildings with a heat loss of up to 19 kW. It consists of a compact outdoor unit with an output of 3.4–12 kW and an indoor unit in the PLUS version. The compressor's frequency inverter continuously adapts the output to the current heat loss of the house.
PLUS indoor unit
The PLUS version combines in a 420 × 255 × 675 mm cabinet (21 kg) the control system, a speed-controlled circulation pump, a flow line sensor, a 3-way heating/DHW diverter valve and an integrated 15 kW backup heater with five steps of 3/6/9/12/15 kW (400 V supply). Domestic hot water is produced in a separate cylinder – the version suits installations with a cylinder from another manufacturer or with a volume above 180 l.
Output and efficiency
- SCOP 4.69 at 35 °C (underfloor heating) and 3.52 at 55 °C (radiators) for the average climate
- COP 4.53 at A7/W35, energy class A+++ at 35 °C and A++ at 55 °C
- flow temperature +15 to +65 °C, heating and DHW production down to an outdoor temperature of −25 °C
- cooling as standard – 12 kW at A35/W18 (SEER 5.22), including a signal for the cooling/heating changeover valve
- R32 refrigerant with GWP 675 (charge 2.2 kg), BLDC twin rotary compressor, electronic expansion valve, stainless steel plate condenser
Outdoor unit
Dimensions 940 × 330 × 1420 mm (W × D × H), weight 111 kg, 1" male-threaded heating water connections. Power supply 400 V 3~N 50 Hz, circuit breaker 10 A. The sound pressure level at a distance of 4 m is 47 dB(A), sound power 64 dB(A). The unit is anchored to a solid foundation and must not stand in an enclosed space; defrost condensate is drained through a heated drain, never into the sewer.
System design
- at least 120 l of heating water must always be available in the system for safe defrosting
- nominal flow 16 l/min, minimum pipe size 28 mm; the flow sensor is included in the delivery
- the controller handles one direct and one mixed circuit; with an expansion card a second mixed circuit or pool heating
- photovoltaic integration via Smart Grid (optional accessory); the HPC software is recommended for sizing
Installation: Installation, electrical connection and work on the refrigerant circuit with the mildly flammable R32 refrigerant may only be carried out by qualified specialists.
Technical data
| Code | IHP203243P |
| Manufacturer | Thermia (IVAR.HP iTec E range) |
| Type | ITEC E-P 12 |
| Indoor unit | PLUS – controller, circulation pump, diverter valve, 15 kW backup heater |
| Heating output | 3.4–12 kW |
| Cooling output (A35/W18) | 12 kW |
| SCOP 35 °C / 55 °C (average climate) | 4.69 / 3.52 |
| COP (A7/W35) | 4.53 |
| Energy class 35 °C / 55 °C | A+++ / A++ |
| Flow temperature | +15 to +65 °C |
| Outdoor temperature for heating | −25 to +35 °C |
| Refrigerant | R32, 2.2 kg |
| Outdoor unit power supply | 400 V 3~N 50 Hz |
| Sound pressure level at 4 m | 47 dB(A) |
| Outdoor unit W × D × H, weight | 940 × 330 × 1420 mm, 111 kg |
Frequently asked questions
What is included in the delivery?
The outdoor unit with condensate drain elbow, the PLUS indoor unit, a ball valve with filter, an outdoor temperature sensor, a flow sensor and documentation. Connection fittings and flexible hoses are ordered separately as accessories.
Which hot water cylinder is connected to the PLUS version?
The PLUS version has no cylinder of its own, but it contains the heating/DHW diverter valve. It is connected to a separate cylinder, for example from another manufacturer or with a volume above 180 l, whose heat exchanger matches the heat pump output.
Can the heat pump also cool?
Yes, the cooling function is included in the basic version; the cooling output is 12 kW at A35/W18. Cooling pipework must be insulated with vapour-tight insulation to prevent condensation.
What maintenance does the heat pump need?
Check the heating system pressure once a month (0.8–1.5 bar), the safety valves at least four times a year and clean the dirt filter twice a year. Keep the outdoor unit free of snow, ice and leaves.
Additional parameters
| Category: | air / water heat pumps |
|---|---|
| Warranty: | 2 years |
| Code: | IHP203243P |
| Manufacturer: | Thermia (IVAR.HP iTec E range) |
| Type: | ITEC E-P 12 |
| Indoor unit: | PLUS – controller, circulation pump, diverter valve, 15 kW backup heater |
| Heating output: | 3.4–12 kW |
| Cooling output (A35/W18): | 12 kW |
| SCOP 35 °C / 55 °C (average climate): | 4.69 / 3.52 |
| COP (A7/W35): | 4.53 |
| Energy class 35 °C / 55 °C: | A+++ / A++ |
| Flow temperature: | +15 to +65 °C |
| Outdoor temperature for heating: | −25 to +35 °C |
| Refrigerant: | R32, 2.2 kg |
| Outdoor unit power supply: | 400 V 3~N 50 Hz |
| Sound pressure level at 4 m: | 47 dB(A) |
| Outdoor unit W × D × H, weight: | 940 × 330 × 1420 mm, 111 kg |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!