THERMIA AURA S2 air-to-air heat pump – heating 3.2 kW down to −30 °C, cooling, Wi-Fi, no DHW
Code: IHP2045834Product detailed description
The THERMIA AURA S2 (code IHP2045834) is an inverter air-to-air heat pump made up of a wall-mounted indoor unit and an outdoor unit. It delivers heat or cooling straight through the air stream, so it needs no water-based heating system – neither radiators nor underfloor heating. It does not prepare domestic hot water (the “no DHW” designation).
Heating and cooling
- heating output 0.8 / 3.2 / 7.0 kW (min. / nominal / max.), COP 4.74, SCOP 4.6 (average climate), class A++
- heating at outdoor temperatures from −30 to +24 °C
- cooling output 0.9 / 2.5 / 3.5 kW, SEER 8.4, class A++; cooling at outdoor temperatures from −15 to +46 °C
- maintenance heating from +8 °C while you are away – protects against damp and mould
Comfort in the room
The indoor unit is only 21.5 cm deep and runs at a sound level of 18–38 dB(A). The increased airflow, with a throw of up to 15 m, spreads the temperature through the room quickly and evenly. The unit has a built-in filter for dust and other particles and built-in Wi-Fi for control through a smartphone app.
Technology and installation
The unit works with R32 refrigerant (GWP 675, charge 0.965 kg) and a hermetic BLDC rotary compressor. The units are connected by 1/4" and 3/8" refrigerant pipes. The supply is single-phase 220–240 V with a 10 A circuit breaker. Installation may only be carried out by a qualified person with electrical training – do not try to install the units yourself.
Technical data
| Code | IHP2045834 |
| Manufacturer | THERMIA / IVAR |
| Type | AURA S2 (air-to-air) |
| Heating output (min. / nom. / max.) | 0.8 / 3.2 / 7.0 kW |
| COP / SCOP | 4.74 / 4.6 (A++) |
| Cooling output (min. / nom. / max.) | 0.9 / 2.5 / 3.5 kW |
| SEER | 8.4 (A++) |
| Refrigerant | R32 (GWP 675), charge 0.965 kg |
| Supply | 1 × 220–240 V, 50 Hz, 10 A breaker |
| Indoor unit sound level | 18–38 dB(A) |
| Outdoor temperature – heating | -30 to +24 °C |
| Indoor unit (W × D × H) | 889 × 215 × 299 mm, 10.4 kg |
| Outdoor unit (W × D × H) | 790 × 285 × 548 mm, 33 kg |
| Refrigerant pipes | 1/4" and 3/8" |
| Domestic hot water | no (no DHW) |
Frequently asked questions
Does the heat pump also prepare hot water, and are radiators needed?
No. It is an air-to-air system that heats or cools the room air directly. It needs no water-based heating system and does not prepare domestic hot water.
Down to what outdoor temperature does it heat?
Heating is stated for outdoor temperatures from −30 to +24 °C and cooling for temperatures from −15 to +46 °C.
Which refrigerant does it use and who may install it?
It uses R32 refrigerant with a charge of 0.965 kg. Installation, including the refrigerant circuit and the electrical connection, should be carried out by a qualified person.
Additional parameters
| Category: | air / air heat pumps |
|---|---|
| Warranty: | 2 years |
| Code: | IHP2045834 |
| Manufacturer: | THERMIA / IVAR |
| Type: | AURA S2 (air-to-air) |
| Heating output (min. / nom. / max.): | 0.8 / 3.2 / 7.0 kW |
| COP / SCOP: | 4.74 / 4.6 (A++) |
| Cooling output (min. / nom. / max.): | 0.9 / 2.5 / 3.5 kW |
| SEER: | 8.4 (A++) |
| Refrigerant: | R32 (GWP 675), charge 0.965 kg |
| Supply: | 1 × 220–240 V, 50 Hz, 10 A breaker |
| Indoor unit sound level: | 18–38 dB(A) |
| Outdoor temperature – heating: | -30 to +24 °C |
| Indoor unit (W × D × H): | 889 × 215 × 299 mm, 10.4 kg |
| Outdoor unit (W × D × H): | 790 × 285 × 548 mm, 33 kg |
| Refrigerant pipes: | 1/4" and 3/8" |
| Domestic hot water: | no (no DHW) |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!