Thermona THERM EL 38
Code: 1605Product detailed description
Electric boiler with output modulation Thermona THERM EL 38
The THERM - EL electric boiler is designed by its construction for hot-water heating systems with forced water circulation. It can be installed in central and single-storey heating systems with forced circulation, in open or closed systems. It is an ecologically clean operation with no flue-gas discharge requirements. Unattended operation is enabled by an external controller or yesther external control/operating element (not included in the boiler's scope of delivery); alternatively, a simple weather-compensation controller or a room temperature controller built directly into the control automatics, maintaining a preset temperature in the selected room, can be used. The electric boiler can be used as a universal heat source for heating in apartments, small family houses and recreational buildings, as well as an alternative source when yesther main heating and hot-water source is used (even for a transitional period) - for heat pumps, accumulation systems, or in previously installed single-storey and central systems, etc. For higher outputs, the boilers can be linked into cascades.
Main advantages of THERM EL electric boilers:
- top-of-the-range microprocessor control
- very quiet operation (switching power relay for heating elements)
- automatic air-vent valve (2 pcs - boiler body + pump)
- option to heat a DHW tank (terminals for an external three-way valve, NTC temperature sensor or tank thermostat)
- modern design
- ergonomic, interactive digital control
- smooth control in 2.5 kW steps (5 kW for the higher output range)
- service-adjustable pump overrun
- pump anti-seizing protection
- PID control
- anti-freeze protection (of the boiler and the system)
- option to connect an external NTC sensor (built-in weather-compensation control)
- connection of a room NTC temperature sensor (automatics acting as a room controller)
- built-in safety switching contactor for all power phases
- option of intelligent cascade connection of all boiler types (up to 32 boilers - with smooth output modulation)
- option of external control via GSM (external modem required)
- option to connect an external OpenTherm-communication controller - a room controller e.g. CR 04 or PT 59, or a higher-level Siemens RVS system
- even loading of heating rods and heating elements
- the power relays are not part of the processor PCB (easy servicing, replaceability); special relays with integrated fastons are used, i.e. high currents do not flow through the printed circuit board
- boiler switching system using an HDO signal (mass remote control / off-peak tariff switching)
- support for external power-input control (load-shedding relay)
- soft start
- integrated three-speed Grundfos UPS 15/60 pump
- integrated 7 l expansion vessel (for the lower output range)
- integrated topping-up and draining of heating water
- integrated safety valve
- digital heating-water pressure sensor (on all types)
- self-diagnostics, unambiguous service reporting of fault states
- option to set boiler parameters (extensive user and service menu)
- digital 3-digit display (shows the set temperatures, pressure, output, fault and other messages)
- 7 additional LEDs for clear signalling of operating states
- default option (immediate switch to factory settings)
| TECHNICAL DATA | unit | EL 8 | EL 15 | EL 23 | EL 30 | EL 38 | EL 45 |
| Rated heat output | kW | 7,5 | 15 | 23 | 30 | 37,5 | 45 |
| Rated current | A | 12 | 24 | 36 | 45 | 57 | 69 |
| Degree of electrical protection | IP4 | 41 | |||||
| Electrical voltage / frequency | V/Hz | 3 x 400 + N + PE/50 | |||||
| Maximum rated current | A | 3x 36 | 3x50A | 3x63A | 3x80A | ||
| Main electrical circuit breaker | A | 16 | 32 | 40 | 50 | 65 | 80 |
| Rated current of control fuse | A | 0,10 | 0,30 | ||||
| Electrical service life of relay | - | 1.105 cycles (16 A, 250V/50 Hz) | |||||
| Mechanical service life of relay | - | 10.106 cycles | |||||
| Heating-water inlet - outlet | - | G 3/4” external | G 1” external | ||||
| Min. operating pressure of heating system | bar | 0,8 | |||||
| Max. operating pressure of heating system | bar | 2,5 | |||||
| Maximum heating-water temperature | oC | 80 | |||||
| Boiler water volume | l | 14,5 | 28 | ||||
| Efficiency at rated output | % | 99 | |||||
| Expansion-vessel volume | l | 7 | on order (located outside the boiler) |
||||
| Maximum number of boilers in cascade | ks | 32 | |||||
| Dimensions (height/width/depth) | mm | 805/475/235 | - | ||||
| Boiler weight without water | kg | 37 | 38 | 39 | 43 | 44 | 45 |
Additional parameters
| Category: | Thermona THERM EL |
|---|---|
| Warranty: | 2 years |
| Product replaced by new one: | https://www.atria.sk/protherm-ray-28ke/ |
| The item has been sold out… | |
Product rating
Be the first who will post an article to this item!
Discussion
List of discussions
About the company
Thermona, s.r.o. is among the leading manufacturers of wall-mounted gas boilers, gas condensing boilers and electric boilers. We have been active in the field of heating technology since 1990 and throughout this time we have remained a modern and dynamically developing company. Proof of this is our THERM products, which meet all the requirements of standards and are subject to thorough final inspections. Customer satisfaction is for us an absolute asset and motivation for the future.
Comfort of your home
Constant development and improvement of products and services we offer is a complete given. We bring maximum comfort to our customers' lives. We believe that the Thermona brand will become synonymous with a comfortable and satisfied life for you and your family.
Tradition and the Czech brand
Since the company's inception, we have operated as a purely Czech manufacturer of heating technology. We are not part of any foreign holding company and we would like to continue in this form as well. Through Therm products, we are building a traditional Czech company based on quality and reliability.