Vaillant WH 40 – hydraulic separator for direct connection under a wall-hung boiler

Vaillant WH 40 (order number 0020248932) is an original hydraulic separator that hydraulically separates the boiler circuit from the heating circuits in multi-circuit systems. This particular version is designed for direct connection under a Vaillant ecoTEC wall-hung condensing boiler (horizontal installation directly beneath the boiler body), without the need for separate wall-mounting brackets – an ideal solution where space in the utility room or boiler room is limited and mounting a standalone separator on the wall would be impractical.

Technical parameters

  • Rated flow rate: 3.5 m³/h
  • Connection: Rp 1 1/4˝
  • Approximate thermal output at 20 K temperature difference: approx. 70 kW
  • Approximate thermal output at 11 K temperature difference: approx. 40 kW
  • Designed for horizontal installation directly under the boiler
  • The package includes a pocket for the temperature sensor, the sensor itself, and complete thermal insulation
  • Built-in drain valve for easy draining during servicing
  • Mounting and connection material required for installation

Why a hydraulic separator is important

A condensing boiler has its own circulation pump designed precisely for the flow rate and pressure loss corresponding to its heat exchanger. If several separate heating circuits with their own pump groups (for example, a combination of a direct group VDM 10 and a mixing group VDM 20 M) are connected directly to the boiler outlet, hydraulic interactions arise between the individual circuits, which can disrupt the stability of flow through the boiler – especially when thermostatic heads close or mixing valves cycle. The WH 40 solves this problem by physically separating the flow of the primary (boiler) circuit from the flow of the secondary (heating) circuits – both sides exchange heat through a common vessel with minimal hydraulic resistance, but their flows do not affect each other.

When to choose the direct under-boiler mounting variant

The Vaillant WH range of separators is available in several versions – with wall-mounting brackets (for example, variants with catalogue numbers from the 306xxx series) or in this version designed for direct connection under a wall-hung boiler without the need for separate wall fixing. This design is particularly advantageous in:

  • Smaller utility rooms or cabinets where there is not enough free wall space to mount a standalone separator
  • New buildings, where a compact arrangement of boiler + separator + manifold in a single vertical line is planned from the start
  • Renovations, where an older boiler is being replaced with a new ecoTEC and hydraulic separation needs to be added without interfering with the layout of the surrounding pipework

Installation and commissioning

  • The WH 40 is mounted directly under the Vaillant ecoTEC wall-hung boiler, onto the flow and return ports with Rp 1 1/4˝ connection
  • The temperature sensor is inserted into the supplied pocket and connected to the boiler controller, which adjusts the operation of its own circulation pump based on its reading
  • The manifold or the pump groups of the individual heating circuits are then connected to the outlet (secondary) side of the separator
  • Once connected, the supplied thermal insulation is fitted, which must cover the entire body including the ports
  • The system must be thoroughly vented before commissioning – residual air inside the separator can cause noise and incorrect sensor operation
  • The built-in drain valve allows for easy partial draining of the system during future servicing without having to drain the entire water volume

Compatibility

The WH 40 is designed to work with Vaillant ecoTEC plus, ecoTEC pro and ecoTEC exclusive wall-hung condensing boilers (including newer models with IoniDetect technology). Manifolds and pump groups from the VDM series with a 120 mm mounting spacing, or a compatible manifold for 2 or 3 circuits, can be connected to the outlet side. For larger systems with more circuits or higher total building heat loss, where a flow rate of 3.5 m³/h would not be sufficient, we recommend considering a more powerful separator from the WH series – for example, the WH 95 with a flow rate of 8.3 m³/h or the WH 160 with a flow rate of 12 m³/h.

Maintenance

  • Check the function of the temperature sensor and its correct connection to the boiler controller once a year
  • Check the tightness of the connections, especially after the first heating season
  • Check the condition of the thermal insulation and that it is fitted correctly without gaps
  • If the system pressure drops, top up water according to the boiler manufacturer's instructions; with harder water, consider installing a softening cartridge
  • Use the drain valve for planned servicing or replacement of components in the secondary circuit

Why choose the original Vaillant solution

The original WH 40 separator is hydraulically and mechanically designed precisely to work with Vaillant ecoTEC boilers – flow capacity, pressure losses and connection dimensions all correspond to the manufacturer's specifications, guaranteeing trouble-free operation and optimal system performance. The direct under-boiler mounting variant also saves space and installation time compared to the bracket version designed for standalone wall mounting.

Overview table – Vaillant WH separator range

ModelFlow rateConnectionApproximate output (ΔT 20K)
WH 272 m³/hRp 1˝~47 kW
WH 40 (this offer)3.5 m³/hRp 1 1/4˝~70 kW
WH 958.3 m³/hRp 2˝~160 kW
WH 16012 m³/hDN 65~230 kW

Choosing the correct separator size depends on the sum of flow rates of all connected heating circuits – undersizing risks increased pressure loss and noise, while significant oversizing results in unnecessarily higher purchase cost without real benefit.

Material design

The WH 40 body is made of high-quality steel or brass casting (depending on the specific design variant), rated for the standard operating pressures and temperatures of heating systems with condensing boilers. The drain valve and connection ports are made of materials resistant to corrosion under normal heating water quality. The supplied thermal insulation made of shaped expanded polypropylene (EPP) reduces heat losses from the separator to the surrounding space and also prevents surface condensation on cooler sections in low-temperature circuits.

Safety and operational reliability

As part of a pressurized hot water system, the WH 40 separator should always be installed in a system equipped with a functional safety valve and a correctly sized expansion vessel. We recommend regularly monitoring the system operating pressure on the boiler display or pressure gauge – a repeated pressure drop may indicate a micro-leak at one of the joints and should be addressed as soon as possible to prevent air from entering the system and the associated problems with water circulation.

Dimensions and space requirements

Thanks to its design for direct mounting under a wall-hung boiler, the WH 40 has a fairly slim, elongated body (approximately 500 mm in length and 114 mm in width including insulation), which fits into the space typically required for mounting a wall-hung boiler, including the clearances required by the manufacturer. This design eliminates the need for additional wall space that would otherwise be taken up by the bracket version of the separator, which is particularly advantageous when installing in smaller utility rooms, alcoves, or attic cabinets.

Effect of the separator on acoustic comfort

In addition to hydraulic separation, the separator also plays an important role in dampening pressure surges and any noise caused by water flow during rapid flow changes (for example, when a thermostatic head suddenly closes). The internal geometry of the WH 40 is designed to dampen these surges and prevent their transmission back towards the boiler, contributing to quieter and smoother operation of the entire system – something especially appreciated by residents of homes where the utility room is close to living spaces.

Relation to boiler output control

The temperature sensor built into the supplied WH 40 pocket provides the boiler controller with information about the temperature in the shared part of the separator, allowing it to more precisely adjust burner output and the operation of its own circulation pump to the current needs of the connected heating circuits. Thanks to this feedback, the boiler does not operate "blindly" based solely on the set heating curve, but also responds to the actual state of the secondary side of the system, contributing to more stable and efficient operation – especially in systems with multiple circuits with different load dynamics (for example, a combination of a fast-responding radiator circuit and a sluggish underfloor heating circuit).

Recommendations for choosing separator size for new projects

When designing a new multi-circuit system, we recommend starting from a preliminary estimate of the total installed boiler output and the number of planned circuits. For typical family houses with a boiler output of up to approx. 25–35 kW and two to three heating circuits, the WH 40 with a flow rate of 3.5 m³/h is generally a sufficient choice. For larger buildings, apartment blocks, or facilities with a higher number of simultaneously operating circuits, we recommend switching to a more powerful WH 95 or WH 160 model, which provide substantial reserve in flow capacity and reduce the risk of future undersizing if the system is expanded.

Frequently asked questions

  • What is the difference between this WH 40 version and the bracket version? This version (0020248932) is designed for direct connection under a wall-hung boiler without the need for wall-mounting brackets, while the bracket version is fixed separately to the wall using supplied brackets. The hydraulic parameters (flow rate 3.5 m³/h, connection Rp 1 1/4˝) are the same for both versions.
  • Do I also need a separate manifold with the WH 40? Yes, the WH 40 only performs the function of hydraulic separation and does not have a built-in manifold. For a multi-circuit system, a separate manifold or pump groups must be connected to the outlet side according to the number of circuits.
  • How do I know if a flow rate of 3.5 m³/h is sufficient for me? We recommend basing this on the sum of flow rates of all connected heating circuits according to the heating project. For larger systems with more circuits, choose a more powerful separator, such as the WH 95 or WH 160.
  • Does the separator's filling need to be topped up or replaced regularly? No, the separator does not contain any replaceable filling – it is a passive hydraulic component. Maintenance consists of checking tightness, the sensor, and the condition of the thermal insulation.
  • Can the WH 40 be used with boilers other than Vaillant? Hydraulically it is possible with compatible connection dimensions, but we recommend verifying compatibility with a technician, as the WH 40 is primarily designed to work with Vaillant ecoTEC boilers.
  • Does installing the WH 40 affect the boiler warranty? Using original Vaillant accessories, installed according to the manufacturer's instructions by an authorized technician, does not affect the boiler warranty – on the contrary, correct hydraulic separation contributes to longer and trouble-free boiler operation.
  • What is the warranty on this product? We provide a standard statutory warranty of 2 years from the date of sale for the WH 40 hydraulic separator.

Summary of technical characteristics

The Vaillant WH 40 in the version for direct mounting under a wall-hung boiler represents an efficient and space-saving hydraulic separation solution for medium-sized multi-circuit heating systems. Thanks to its flow capacity of 3.5 m³/h and Rp 1 1/4˝ connection, it covers the needs of most typical family houses with two to three heating circuits, while its compact design without the need for separate wall brackets simplifies installation and saves space in the utility room. Combined with suitable pump groups from the VDM series and a manifold for the required number of circuits, you get a complete, mutually matched solution from a single manufacturer, with guaranteed compatibility of all hydraulic and mechanical parameters throughout the entire system, from the boiler through the separator to the individual pump groups of specific heating circuits.

Additional note on ordering the sensor

The temperature sensor is included as standard in the WH 40 package, and we recommend always connecting it to the boiler controller to maintain full functionality of the hydraulic separation, including the feedback for controlling boiler output according to the current state of the secondary side of the system. Using original Vaillant accessories, installed according to the manufacturer's instructions by an authorized technician, does not affect the warranty on the boiler itself – on the contrary, correct hydraulic separation contributes to its longer and trouble-free operation.

Additional parameters

Category: Vaillant – pump groups and accessories
Warranty: 2 years
Product type: Hydraulic separator
Rated flow rate: 3.5 m³/h
Connection: Rp 1 1/4˝
Approximate output at ΔT 20K: approx. 70 kW
Approximate output at ΔT 11K: approx. 40 kW
Mounting: direct, under the wall-hung boiler
Package includes: sensor pocket, sensor, thermal insulation, drain valve
Brand: Vaillant
Country of origin: Germany
Warranty: 2 years

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Discussion

Be the first who will post an article to this item!

Do not fill out this field

About the company

The Vaillant Group is synonymous with heating and hot water preparation, placing particular emphasis on quality, reliability and user comfort. Its heating technology products are present in more than 100 countries around the world. The group unites the brands Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval and Protherm. Each of these brands has extensive experience in the production of heating equipment, as most of them have been active in this segment for more than 80 years. With its 140 years of market presence, the brand Vaillant is among the largest and most significant. It has long been a market leader and a pioneer in the development and innovation of heating technologies in Europe. The Vaillant Group has an extensive network of sales representatives and thousands of satisfied customers around the world.

The extensive portfolio of the Vaillant Group includes modern heating technologies that are energy-saving, efficient and contribute to environmental protection. Thanks to a wide range of products and models, every customer can find exactly what they need here. The range includes wall-hung and floor-standing boilers, hot water storage tanks or electrical appliances. In the market of wall-hung boilers, the company is even number one in Europe with a 26 percent market share. The Vaillant Group is not specialized only in the development and production of boilers; its product portfolio also includes technologies that use renewable energy sources, such as solar systems or the most modern heat pumps and air conditioners. It also offers recovery or cogeneration units or zeolite heat pumps to users.

Vaillant Group thinks ahead every day and offers individual solutions for every need and type of energy. Its success is also based on research and development, which always takes place in line with the wishes of customers. The company's research and development department is among the largest and above all the most creative departments in this segment. The team of developers is constantly working on new devices and technological systems that are increasingly easy to operate and already meet the demands of tomorrow. Whether it is about energy solutions of the future or about the best way to use fossil fuels, the company Vaillant Group tries to anticipate new trends and to be always one step ahead of others. Proof of this is the registration of up to 100 new patents every year. In the field of production, the company places the greatest emphasis on achieving the highest quality of boilers, which represents perfection in every detail.

The Vaillant Group has its presence in most countries of the world. Slovakia is no exception, where the company Vaillant Group Slovakia, s. r. o. is located, representing the brands Vaillant and Protherm. Heating equipment of the Vaillant Group is produced in seven production plants, two of which are located on our territory. These factories employ more than 1,300 people in total. The production plant Protherm Production with its headquarters in Skalice specializes in the production of electric and floor-standing boilers for all brands belonging to the Vaillant Group. It can also boast its own research and development center, which is among the most modern in Europe. The second production plant in Slovakia is Vaillant Industrial Slovakia in Trenčianske Stankovce, which produces modules for wall-hung boilers for the entire group.

History of the company Vaillant

The history of the company Vaillant goes back to the year 1874, when it was founded by Johann Vaillant in Remscheid, Germany. Since then, the company Vaillant has been a leader in the field of heating and ventilation technologies.

History of the company Vaillant 

1874 Plumber Johann Vaillant founded the company.

1894 Patented for the invention of a gas water heater with a "closed system" design.

1899 Registered company logo, the Easter Bunny.

1905 Development of a wall-mounted water heater, patented under the designation "Geyser".

1924 Development of a wall-mounted boiler for heating.

1955 Production of the millionth appliance after the end of the Second World War.

1960 Production of electrical appliances begins.

1967 Development of a combined wall-mounted boiler.

1974 11 million appliances sold since 1974.

1992 Establishment of subsidiary companies – in the Czechoslovak Republic, Hungary, Poland and Turkey.

1993 Separation of Czechoslovakia leads to the creation of a separate sales representation in Slovakia.

1999 Anniversary, 125th anniversary of the founding of the company, 40 million appliances sold in the entire history of the company.

2001 The Vaillant Group is formed, covering eight significant manufacturers of heating equipment in Europe, including the boiler manufacturer Protherm in Slovakia.

2003 The Vaillant Group production plant in Skalice specializes in the production of floor-standing boilers also for other brands belonging to the VG group.

2004 Vaillant Group opens a new production plant in Trenčín, Slovakia, for the production of hydraulic groups for wall-hung boilers.

2009 10,000,000 modules for heating equipment produced at the VG Trenčín plant.

Easter Bunny in the logo - intended for the success of the company

Pink dwarfs and cute animals stand around and admire the miracle of the egg. Johann Vaillant is fascinated by the scene and decides to buy both the picture and the copyright. For Vaillant, this means the establishment of its brand and an extremely successful story.

Very distinctive brand profile

Since 1899, the motif has adorned all products, catalogs and brochures. In a few short years, Vaillant built an excellent reputation that spread throughout Germany and even beyond its borders. Vaillant gave its logo clear lines and outlines. "The Bunny in the Egg" remains the central theme, but the word "Vaillant" is added.

Many Germans know that the Vaillant Bunny belongs to a company based in North Rhine-Westphalia. Moreover: more than 70% of all Germans have heard of the company Vaillant. In Austria and the Netherlands, the company achieves similar results for its image.

Sustainability 

As a forward-looking, family-owned company, we accept special responsibility for the environment, for our employees and for society. We are convinced that economic success, sustainable and profitable growth are inseparably linked to a commitment to social and ecological standards.

In order to fulfill this commitment, we are committed to carrying out our activities in a sustainable manner within the strategic S.E.E.D.S. Program (Sustainability in Environment, Employees, Development & Products and Society). The definition of these areas of interest is based on a comprehensive understanding of sustainability, in which we also take into account key issues of our core activities.

 

 

 

Vytvořil Shoptet | Design Shoptak.cz.