Vaillant safety group for wall-mounted cylinders, up to 6 bar, without pressure regulator, chrome
Code: 0020174068Product detailed description
Vaillant safety group for wall-mounted cylinders, up to 6 bar, without pressure regulator, chrome
This Vaillant safety group is intended for wall-mounted (hanging) domestic hot water cylinders with a nominal operating pressure corresponding to an opening (relief) pressure of up to 6 bar. It is a combined safety fitting that is an essential part of every closed (pressurised) storage water heating installation – its main task is to protect the cylinder from a dangerous excess of operating pressure. Unlike the variant with an integrated pressure regulator (intended for higher inlet pressures from the public water mains), this version is without a pressure regulator – meaning it is suitable for installations where the inlet pressure from the water supply is already, by itself, within a safe range for the given cylinder, or where the regulation (reduction) of inlet pressure is handled by a separate, already existing pressure reducing valve elsewhere in the piping.
Why a cylinder absolutely needs a safety group
A closed (pressurised, non-flow-through) domestic hot water cylinder is, from a safety point of view, a pressure vessel – as water is heated in an enclosed space, its thermal expansion, without the possibility of release or compensation, creates increasing pressure inside the cylinder. Without a functioning safety relief element, this pressure increase could, under certain circumstances (for example a thermostat fault, or the simultaneous effect of high inlet pressure from the water mains), exceed the structural limit of the cylinder, with the risk of damage. The safety group therefore includes a safety (relief) valve set to a precisely defined opening pressure – in this case up to 6 bar – which automatically opens when this value is exceeded and safely releases the excess pressure out of the system, into a suitably routed drain.
This safety function is not an optional add-on, but a basic and, in the vast majority of countries, also normatively required part of every installation of a closed pressurised cylinder. Installing a cylinder without a functioning safety group corresponding to its operating pressure would not comply with standard professional practice or with the requirements for safe operation of pressure equipment.
Composition of this particular safety group
In addition to the safety relief valve itself, this safety group includes a check (non-return) valve, which prevents backflow of heated water from the cylinder into the public water mains – thereby protecting the quality of drinking water in the public network from potential contamination from a private installation. It usually also includes a test/drain lever or tap, which allows regular manual verification of the safety valve's function according to the manufacturer's instructions. Since this version does not include an integrated pressure regulator (reducing valve), its internal arrangement is simpler than that of the variant with pressure regulation, which can be an advantage in terms of lower flow resistance of the fitting during normal operation.
When to choose the version without a pressure regulator
The version without an integrated pressure regulator is suitable primarily when the inlet water pressure from the public mains (or from a private water source, if the property is connected to its own water source) is permanently within a safe range corresponding to the nominal operating pressure of the cylinder, or when pressure reduction is already handled by a separate reducing valve located earlier in the piping (for example on the main supply into the building). Before installing this version, it is essential to verify the current and maximum possible inlet water pressure at the installation site – if the inlet pressure from the mains fluctuates or permanently exceeds the safe value for the given cylinder, it is advisable to choose a safety group with an integrated pressure regulator instead of this version, or to add a separate pressure reducing valve upstream of this safety group.
Material and surface finish
The safety group is made with a body of brass – a proven material for fittings in contact with drinking water thanks to its corrosion resistance and good machinability – with a chrome surface finish. Chrome plating serves both an aesthetic function (the fitting retains a shiny, clean appearance in the long term, even in cases where it is visible after installation) and increases the surface's resistance to mechanical wear and corrosion compared to an untreated brass surface.
Installation
The safety group is installed on the cold water supply to the cylinder, in accordance with the manufacturer's installation instructions and with the requirements applicable to the installation of pressure equipment. It is crucial to correctly route the discharge (relief) pipe from the safety valve to a suitable, visible and safe drainage point, so that any water discharge upon activation of the safety valve does not cause damage to surrounding spaces or equipment. Correct installation orientation (flow direction marked on the body of the fitting) is also important, as is sufficient free space for future access to the test lever for regular function verification. This installation should be carried out exclusively by a qualified installer or plumber authorised to work on drinking water systems and pressure equipment.
Compatibility
This safety group is designed for a range of Vaillant wall-mounted (hanging) domestic hot water cylinders with an operating pressure corresponding to an opening pressure of up to 6 bar. Before ordering, we recommend verifying the exact type and nominal operating pressure of your specific cylinder according to the technical documentation or the type plate, or contacting us with the exact designation of the appliance to verify the correct choice of safety group – especially with regard to whether a version with or without a pressure regulator is more suitable for your installation.
Maintenance
According to the manufacturer's instructions and standard professional practice, safety groups require regular manual verification of the safety valve's function using the test lever – this operation verifies that the valve is not clogged with deposits or otherwise blocked and can genuinely relieve excess pressure when needed. We recommend following the manufacturer's instructions for the frequency of this test; it is usually an operation carried out at regular intervals, for example during the annual service of the appliance. In areas with harder water, it is also advisable to pay increased attention to possible limescale build-up in the fitting, which can affect the function of the safety valve over the years – if reduced function is detected, we recommend contacting a service technician. The chrome-plated surface should be cleaned with mild, non-abrasive cleaning agents intended for chrome-plated surfaces.
Why choose an original Vaillant safety group
The safety group is a safety-critical element of the installation, which is why using an original, manufacturer-verified component with a precisely defined and certified opening pressure is essential for the safe operation of the cylinder. An original Vaillant part guarantees the correct combination of parameters (opening pressure, compatible connection dimensions) corresponding to the given cylinder range, which cannot always be clearly guaranteed with generic alternatives from other sources.
Why it is important to choose a safety group exactly according to the cylinder's pressure class
Vaillant, as well as other cylinder manufacturers, offers safety groups in several opening pressure variants – for example lower values (such as this version up to 6 bar) for cylinders with a lower nominal operating pressure, and higher values for cylinders with a higher nominal operating pressure. Confusing these variants is not just a matter of technical mismatch – with an undersized safety group (with too low an opening pressure relative to the cylinder's actual operating pressure), unnecessary, repeated leakage of water and energy would occur during normal operation, while with an oversized safety group (with too high an opening pressure), the cylinder would not be sufficiently protected against exceeding its actual structural limit. Verifying the correct pressure class before ordering and installation is therefore an essential step.
Frequently Asked Questions
Why does this safety group not include a pressure regulator?
This version is intended for installations where the inlet water pressure from the mains is already within a safe range for the given cylinder, or where pressure reduction is handled by a separate reducing valve earlier in the piping. If your inlet pressure fluctuates or is high, we recommend the version with an integrated pressure regulator.
What does an opening pressure of "up to 6 bar" mean?
This is the pressure at which the safety valve automatically opens and releases excess pressure from the cylinder. This value must correspond to the maximum permissible operating pressure of the specific cylinder.
How do I know if my cylinder needs exactly this version?
Check the nominal operating pressure of the cylinder on its type plate or in the technical documentation. If in doubt, contact us with the exact type designation of the appliance – we will be happy to help you choose.
Do I need to regularly test the function of the safety valve?
Yes, regular manual verification of the function using the test lever is a standard and recommended procedure that ensures the valve is not clogged and actually works when needed.
Can the property owner install the safety group themselves?
No, installation should be carried out exclusively by a qualified installer authorised to work on drinking water systems and pressure equipment, as this is a safety-critical element of the installation.
What is the warranty on this part?
We provide the standard statutory 2-year warranty on this original Vaillant part.
Broader context – safety of pressure equipment and protection of drinking water
The safety of pressurised domestic hot water storage systems is governed by generally recognised technical standards and professional practice throughout the European Union and Slovakia – closed (pressurised) cylinders must be equipped with a functioning safety group corresponding to their nominal operating pressure, and this requirement applies regardless of the manufacturer of the specific cylinder. It is also generally required practice to prevent backflow of heated or otherwise contaminated water from a domestic installation into the public water mains, which is ensured precisely by the integrated check valve within the safety group.
When modernising an older installation, where the original safety group was fitted many years ago, it is advisable to consider checking or replacing it, as older fittings may be affected by limescale build-up or worn seals, which can reduce their functionality over time. Replacing it with a new, original part corresponding to the nominal pressure of your cylinder is a relatively inexpensive measure compared to the risk posed by a non-functioning safety fitting on pressure equipment.
When ordering this safety group for your specific cylinder, we recommend contacting our sales team with the exact type designation of the cylinder as well as information about the current pressure in your water supply system – we will be happy to help you verify that this version without a pressure regulator is indeed the right choice for your installation, or recommend an alternative with an integrated regulator.
How to determine the actual inlet pressure in your water supply system
Before deciding between the version with a pressure regulator and without one, it is advisable to know not only the immediate value but also the maximum possible pressure that may occur at the given location during the day or over the course of the year – public water networks commonly show pressure fluctuations depending on the time of day (for example, at night, when consumption is low, pressure may temporarily rise), on the altitude and position of the connection point within the pressure zone, or on operational interventions by the network operator. Measuring with a pressure gauge directly on the supply into the building, ideally repeatedly at different times of day, provides a more reliable basis for the decision than a single reading at one moment. If the measured values regularly exceed the safe limit for the given cylinder, or if you are unsure about the stability of the pressure throughout the year, a safer choice is the safety group version with an integrated pressure regulator, or the addition of a separate pressure reducing valve at the inlet to the building.
Typical mistakes when choosing and installing a safety group
The most common mistakes encountered in practice include using a safety group with an incorrect opening pressure relative to the actual type of cylinder (for example, confusing the version up to 6 bar with the version over 6 bar or vice versa), incorrect routing of the discharge pipe from the safety valve (for example, blocking it, too long or rising piping without sufficient fall, or routing it to a place where any water discharge would cause damage), and neglecting regular testing of the safety valve's function throughout the cylinder's service life. None of these mistakes may be immediately apparent during normal operation, but at a critical moment (for example, in the event of a cylinder thermostat fault) they can have serious consequences – we therefore recommend paying appropriate attention to the selection and installation of this seemingly simple fitting from the very beginning of the project.
The safety group as part of long-term care for the cylinder
The safety group should be seen not as a one-time installed component that is forgotten after installation, but as part of the long-term care of the hot water cylinder throughout its service life, which for quality Vaillant cylinders can exceed ten to fifteen years. During this time, the fitting repeatedly undergoes temperature and pressure cycles, which naturally leads to gradual wear of seals and mechanical parts. Including a check of the safety group in the regular annual service inspection of the cylinder is therefore a simple and inexpensive way to prevent the surprise of a non-functioning safety element at the very moment the cylinder needs it most.
Frequently Asked Questions – additional
What happens if I use a safety group with the wrong opening pressure?
A pressure setting that is too low causes unnecessary, frequent discharge of water during normal operation, while a setting that is too high does not provide the cylinder with sufficient protection against exceeding its structural limit. It is therefore always necessary to choose the version that exactly corresponds to the nominal pressure of your cylinder.
How often should I have the safety group checked?
We recommend including a check of the safety group's function in the regular annual service inspection of the cylinder, carried out by an authorised service technician.
Additional parameters
| Category: | Vaillant – valves, insulation and installation kits |
|---|---|
| Warranty: | 2 years |
| Brand: | Vaillant |
| Type: | Safety group for wall-mounted cylinders |
| Opening (relief) pressure: | up to 6 bar |
| Pressure regulator: | not included (version without regulator) |
| Body material: | brass |
| Surface finish: | chrome |
| Components: | safety valve, check valve, test lever |
| Intended use: | wall-mounted (hanging) domestic hot water cylinders |
| Installation: | exclusively by a qualified installer |
| Country of origin: | Germany |
| Warranty: | 2 years |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
About the company
The Vaillant Group is synonymous with heating and hot water preparation, placing particular emphasis on quality, reliability and user comfort. Its heating technology products are present in more than 100 countries around the world. The group unites the brands Vaillant, Saunier Duval, AWB, Bulex, DemirDöküm, Glow worm, Hermann Saunier Duval and Protherm. Each of these brands has extensive experience in the production of heating equipment, as most of them have been active in this segment for more than 80 years. With its 140 years of market presence, the brand Vaillant is among the largest and most significant. It has long been a market leader and a pioneer in the development and innovation of heating technologies in Europe. The Vaillant Group has an extensive network of sales representatives and thousands of satisfied customers around the world.
The extensive portfolio of the Vaillant Group includes modern heating technologies that are energy-saving, efficient and contribute to environmental protection. Thanks to a wide range of products and models, every customer can find exactly what they need here. The range includes wall-hung and floor-standing boilers, hot water storage tanks or electrical appliances. In the market of wall-hung boilers, the company is even number one in Europe with a 26 percent market share. The Vaillant Group is not specialized only in the development and production of boilers; its product portfolio also includes technologies that use renewable energy sources, such as solar systems or the most modern heat pumps and air conditioners. It also offers recovery or cogeneration units or zeolite heat pumps to users.
Vaillant Group thinks ahead every day and offers individual solutions for every need and type of energy. Its success is also based on research and development, which always takes place in line with the wishes of customers. The company's research and development department is among the largest and above all the most creative departments in this segment. The team of developers is constantly working on new devices and technological systems that are increasingly easy to operate and already meet the demands of tomorrow. Whether it is about energy solutions of the future or about the best way to use fossil fuels, the company Vaillant Group tries to anticipate new trends and to be always one step ahead of others. Proof of this is the registration of up to 100 new patents every year. In the field of production, the company places the greatest emphasis on achieving the highest quality of boilers, which represents perfection in every detail.
The Vaillant Group has its presence in most countries of the world. Slovakia is no exception, where the company Vaillant Group Slovakia, s. r. o. is located, representing the brands Vaillant and Protherm. Heating equipment of the Vaillant Group is produced in seven production plants, two of which are located on our territory. These factories employ more than 1,300 people in total. The production plant Protherm Production with its headquarters in Skalice specializes in the production of electric and floor-standing boilers for all brands belonging to the Vaillant Group. It can also boast its own research and development center, which is among the most modern in Europe. The second production plant in Slovakia is Vaillant Industrial Slovakia in Trenčianske Stankovce, which produces modules for wall-hung boilers for the entire group.

History of the company Vaillant
The history of the company Vaillant goes back to the year 1874, when it was founded by Johann Vaillant in Remscheid, Germany. Since then, the company Vaillant has been a leader in the field of heating and ventilation technologies.
History of the company Vaillant
1874 Plumber Johann Vaillant founded the company.
1894 Patented for the invention of a gas water heater with a "closed system" design.
1899 Registered company logo, the Easter Bunny.
1905 Development of a wall-mounted water heater, patented under the designation "Geyser".
1924 Development of a wall-mounted boiler for heating.
1955 Production of the millionth appliance after the end of the Second World War.
1960 Production of electrical appliances begins.
1967 Development of a combined wall-mounted boiler.
1974 11 million appliances sold since 1974.
1992 Establishment of subsidiary companies – in the Czechoslovak Republic, Hungary, Poland and Turkey.
1993 Separation of Czechoslovakia leads to the creation of a separate sales representation in Slovakia.
1999 Anniversary, 125th anniversary of the founding of the company, 40 million appliances sold in the entire history of the company.
2001 The Vaillant Group is formed, covering eight significant manufacturers of heating equipment in Europe, including the boiler manufacturer Protherm in Slovakia.
2003 The Vaillant Group production plant in Skalice specializes in the production of floor-standing boilers also for other brands belonging to the VG group.
2004 Vaillant Group opens a new production plant in Trenčín, Slovakia, for the production of hydraulic groups for wall-hung boilers.
2009 10,000,000 modules for heating equipment produced at the VG Trenčín plant.
Easter Bunny in the logo - intended for the success of the company
Pink dwarfs and cute animals stand around and admire the miracle of the egg. Johann Vaillant is fascinated by the scene and decides to buy both the picture and the copyright. For Vaillant, this means the establishment of its brand and an extremely successful story.

Very distinctive brand profile
Since 1899, the motif has adorned all products, catalogs and brochures. In a few short years, Vaillant built an excellent reputation that spread throughout Germany and even beyond its borders. Vaillant gave its logo clear lines and outlines. "The Bunny in the Egg" remains the central theme, but the word "Vaillant" is added.

Many Germans know that the Vaillant Bunny belongs to a company based in North Rhine-Westphalia. Moreover: more than 70% of all Germans have heard of the company Vaillant. In Austria and the Netherlands, the company achieves similar results for its image.
Sustainability
As a forward-looking, family-owned company, we accept special responsibility for the environment, for our employees and for society. We are convinced that economic success, sustainable and profitable growth are inseparably linked to a commitment to social and ecological standards.
In order to fulfill this commitment, we are committed to carrying out our activities in a sustainable manner within the strategic S.E.E.D.S. Program (Sustainability in Environment, Employees, Development & Products and Society). The definition of these areas of interest is based on a comprehensive understanding of sustainability, in which we also take into account key issues of our core activities.