Twin-head dry-rotor pump DAB DKLM 65-600 T, DN 65 flanges
Code: 105210114Product detailed description
DAB DKLM 65-600 T (code 105210114) is a twin-head dry-rotor pump from DAB, DKLM series, in a flanged design with DN 65 flanges. It belongs to the pumps for heating, air-conditioning, solar and hot-water systems.
Designation and hydraulics
- DN 65 – nominal size of the flanges, PN 6 / PN 10 flanges with measuring ports
- 600 – maximum head in centimetres, i.e. about 6 m
- T – three-phase motor 3 × 230–400 V, 50 Hz
For the whole KL/DKL series the manufacturer states a flow of 2 to 67 m³/h and a head of up to 13.7 m.
Motor
Enclosed four-pole asynchronous motor cooled by external ventilation, protection rating IP 55, insulation class F, built to CEI 2-3. With three-phase motors an external overload protection has to be installed.
Materials and operation
Pump casing and lantern are cast iron, the impeller is technopolymer. The motor shaft is AISI 316 and the mechanical seal is silicon carbide (SiC/SiC). The pumped liquid should be clean, free of solid and abrasive matter, non-aggressive, non-viscous, non-crystallising and chemically neutral; its temperature may be −15 to +120 °C and the operating pressure up to 10 bar. The connection is a job for a qualified electrician.
Technical data
| Code | 105210114 |
| Manufacturer | DAB |
| Type | DAB.DKLM |
| Model | DKLM 65-600 T |
| Design | twin-head, flanged |
| Flange nominal size | DN 65 (PN 6 / PN 10) |
| Max. head (per designation) | ≈ 6 m |
| Motor poles | 4 |
| Power supply | 3 × 230–400 V, 50 Hz |
| Liquid temperature | −15 … +120 °C |
| Max. operating pressure | 10 bar |
| Protection rating / insulation class | IP 55 / F |
| Impeller material | technopolymer |
Frequently asked questions
What does the number 600 in the designation DKLM 65-600 T mean?
It is the maximum head in centimetres, so according to the designation the pump reaches about 6 m. The actual duty point depends on the flow in the system.
What supply does the pump DKLM 65-600 T require?
The designation T means a three-phase motor supplied with 3 × 230–400 V, 50 Hz; a four-pole motor turns more slowly than a two-pole one.
Which liquid is suitable for this pump?
Clean water free of solid and abrasive matter, non-aggressive, non-viscous and non-crystallising, at −15 to +120 °C and an operating pressure of up to 10 bar.
Does the pump motor need external overload protection?
Yes, with three-phase motors (version T) an external overload protection has to be installed. The single-phase version M has built-in thermal protection and a capacitor.
Additional parameters
| Category: | DAB.DKLM,DKLP,KLM,KLP - Dry-Rotor Pumps - Various Systems |
|---|---|
| Warranty: | 2 years |
| Code: | 105210114 |
| Manufacturer: | DAB |
| Type: | DAB.DKLM |
| Model: | DKLM 65-600 T |
| Design: | twin-head, flanged |
| Flange nominal size: | DN 65 (PN 6 / PN 10) |
| Max. head (per designation): | ≈ 6 m |
| Motor poles: | 4 |
| Power supply: | 3 × 230–400 V, 50 Hz |
| Liquid temperature: | −15 … +120 °C |
| Max. operating pressure: | 10 bar |
| Protection rating / insulation class: | IP 55 / F |
| Impeller material: | technopolymer |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!