Twin-head dry-rotor pump DAB DKLM 80-300 T, DN 80 flanges

Code: 105210134
Not rated Rating details
2 434,10 € –20 %
Zdvojené suchobežné čerpadlo DAB DKLM 80-300 T, príruby DN 80
2 434,10 € –20 % 1 947,28 € / pcs 1 583,15 € excl. VAT Measure price:
International delivery
To order (1-2 weeks)

Detailed information

Product detailed description

DAB DKLM 80-300 T (code 105210134) is a twin-head dry-rotor pump from DAB, DKLM series, in a flanged design with DN 80 flanges. It belongs to the pumps for heating, air-conditioning, solar and hot-water systems.

Designation and hydraulics

  • DN 80 – nominal size of the flanges, PN 6 / PN 10 flanges with measuring ports
  • 300 – maximum head in centimetres, i.e. about 3 m
  • T – three-phase motor 3 × 230–400 V, 50 Hz

For the whole KL/DKL series the manufacturer states a flow of 2 to 67 m³/h and a head of up to 13.7 m.

Motor

Enclosed four-pole asynchronous motor cooled by external ventilation, protection rating IP 55, insulation class F, built to CEI 2-3. With three-phase motors an external overload protection has to be installed.

Materials and operation

Pump casing and lantern are cast iron, the impeller is technopolymer. The motor shaft is AISI 316 and the mechanical seal is silicon carbide (SiC/SiC). The pumped liquid should be clean, free of solid and abrasive matter, non-aggressive, non-viscous, non-crystallising and chemically neutral; its temperature may be −15 to +120 °C and the operating pressure up to 10 bar. The connection is a job for a qualified electrician.

Technical data

Code105210134
ManufacturerDAB
TypeDAB.DKLM
ModelDKLM 80-300 T
Designtwin-head, flanged
Flange nominal sizeDN 80 (PN 6 / PN 10)
Max. head (per designation)≈ 3 m
Motor poles4
Power supply3 × 230–400 V, 50 Hz
Liquid temperature−15 … +120 °C
Max. operating pressure10 bar
Protection rating / insulation classIP 55 / F
Impeller materialtechnopolymer

Frequently asked questions

What does the number 300 in the designation DKLM 80-300 T mean?
It is the maximum head in centimetres, so according to the designation the pump reaches about 3 m. The actual duty point depends on the flow in the system.

What supply does the pump DKLM 80-300 T require?
The designation T means a three-phase motor supplied with 3 × 230–400 V, 50 Hz; a four-pole motor turns more slowly than a two-pole one.

Which liquid is suitable for this pump?
Clean water free of solid and abrasive matter, non-aggressive, non-viscous and non-crystallising, at −15 to +120 °C and an operating pressure of up to 10 bar.

Does the pump motor need external overload protection?
Yes, with three-phase motors (version T) an external overload protection has to be installed. The single-phase version M has built-in thermal protection and a capacitor.

Additional parameters

Category: DAB.DKLM,DKLP,KLM,KLP - Dry-Rotor Pumps - Various Systems
Warranty: 2 years
Code: 105210134
Manufacturer: DAB
Type: DAB.DKLM
Model: DKLM 80-300 T
Design: twin-head, flanged
Flange nominal size: DN 80 (PN 6 / PN 10)
Max. head (per designation): ≈ 3 m
Motor poles: 4
Power supply: 3 × 230–400 V, 50 Hz
Liquid temperature: −15 … +120 °C
Max. operating pressure: 10 bar
Protection rating / insulation class: IP 55 / F
Impeller material: technopolymer