IVAR.PUFFER PSR 500 heating water buffer tank with one built-in heat exchanger – 476 l
Code: 1V13509Product detailed description
Heat storage with an additional source via heat exchanger
The IVAR.PUFFER PSR 500 stores 476 l of heating water in a closed system. In addition to the sockets for direct connection of the heat source and heating circuits, it has a fixed coil heat exchanger in its lower part that transfers heat into the tank from a separate circuit, such as a solar system. Boilers, heat pumps or fireplace inserts can also serve as heat sources.
Coil heat exchanger
- heat transfer surface 1.8 m², water content of the coil 10.4 l
- max. absorbed output 45 kW, required flow rate 1.9 m³/h
- pressure drop 73 mbar, max. operating pressure 10 bar
- coil inlet and outlet 1"
Tank
- steel without internal lining, painted on the outside, max. 3 bar and 95 °C
- removable 100 mm VLIES insulation (B-s2,d0), energy class C
- 6/4" sockets for flow and return of the heat source and heating system, 5/4" air vent, 1/2" thermometer and probe
Siting and installation
The tank belongs in a closed, ventilated room with a year-round temperature of at least +5 °C. A level, load-bearing floor is sufficient, and the tank is levelled with spacer feet. Empty, it weighs 140 kg; with insulation it is 1775 mm high and 850 mm in diameter, and the tilt height is 1750 mm. The insulation is fitted only at the installation site.
The safety valve of the tank circuit must open below 3 bar, that of the coil circuit below 10 bar. The manufacturer recommends an expansion vessel of 25 to 50 l and limiting the maximum temperature on the heat source side. Installation is carried out by a qualified company with a commissioning report; the tank is desludged once a year.
Technical data
| Code | 1V13509 |
| Manufacturer | IVAR |
| Type | IVAR.PUFFER PSR 500 |
| Total capacity | 476 l |
| Coil surface area | 1.8 m² |
| Coil water content | 10.4 l |
| Max. absorbed output of coil | 45 kW |
| Required flow rate | 1.9 m³/h |
| Coil pressure drop | 73 mbar |
| Max. pressure tank / coil | 3 / 10 bar |
| Max. operating temperature | 95 °C |
| Thermal insulation | VLIES 100 mm, removable |
| Height with insulation | 1775 mm |
| Diameter with insulation | 850 mm |
| Empty weight | 140 kg |
Frequently asked questions
What is the heat exchanger in the IVAR.PUFFER PSR 500 tank for?
The fixed 1.8 m² coil heat exchanger transfers heat from a separate circuit, such as a solar circuit, to the stored water. The manufacturer specifies a max. absorbed output of 45 kW and a required flow rate of 1.9 m³/h.
What pressures can the tank and coil withstand?
The tank is rated for 3 bar, the coil for 10 bar, and the maximum temperature is 95 °C. Each circuit must have a safety valve with an opening pressure below this limit.
What kind of base does the tank need?
A level floor with sufficient load-bearing capacity is enough; the 476 l tank is levelled with spacer feet. The room must be closed, ventilated and at least +5 °C.
Additional parameters
| Category: | with integrated heat exchanger |
|---|---|
| Warranty: | 2 years |
| Weight: | 140 kg |
| Code: | 1V13509 |
| Manufacturer: | IVAR |
| Type: | IVAR.PUFFER PSR 500 |
| Total capacity: | 476 l |
| Coil surface area: | 1.8 m² |
| Coil water content: | 10.4 l |
| Max. absorbed output of coil: | 45 kW |
| Required flow rate: | 1.9 m³/h |
| Coil pressure drop: | 73 mbar |
| Max. pressure tank / coil: | 3 / 10 bar |
| Max. operating temperature: | 95 °C |
| Thermal insulation: | VLIES 100 mm, removable |
| Height with insulation: | 1775 mm |
| Diameter with insulation: | 850 mm |
| Empty weight: | 140 kg |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
IVAR designs, develops and manufactures highly energy-efficient heating and plumbing systems. We have over 10,000 catalogue items - mass-produced products and unique items - in addition to customised systems and combinations of complex products. And it’s all “Made in Italy”.
Vision
To make life easier for our clients, our clients' customers and our employees, thanks to our ability to be constantly innovative.
Mission
To design and manufacture advanced hydronic solutions that reduce installation complexity and energy consumption.
“Made in Italy” adds value
IVAR has been producing heating and plumbing system components since 1985: valves for heating bodies, direct heat metering modules, heat cost allocators, pipes and fittings, substations for heating systems, distribution manifolds, radiant panel systems, and components for solar and geothermal systems. And it’s all “Made in Italy”.
Over 200 people are employed at our manufacturing facilities in Prevalle (in northern Italy’s Brescia province). The site has been designed to streamline our many production and operational stages.
The Italian headquarters also acts as a hub for the wider IVAR Group, set up with the goal of distributing products beyond Italy’s borders. The group now has 11 branches, in Australia, Belgium, China, Germany, the United Kingdom, the Czech Republic, Romania, Slovakia, Spain, the United States and Tunisia.
Know How
Research, development and numerous laboratory tests guarantee that our clients’ requests can be translated into new high-efficiency products.
The stages required for production take place internally, beginning with hot forming, which is carried out at our subsidiary Valmon Stampati. Our continuous implementation of projects under the Industry 4.0 initiative also allows us to take full advantage of new releases in technology and IT to improve our manufacturing efficiency.
As a company, IVAR is constantly evolving. Every day, we invest in strengthening our products, in improving our production processes and in attaining new patents and certifications.