IVAR.FLAT-3000 flat underground rainwater tank, 3000 l, low-profile – SALE
Code: S064Product detailed description
The IVAR.FLAT-3000 (code S064) is a low-profile tank with a capacity of 3000 litres for underground installation. It retains rainwater or serves as a store of non-potable service water for the building, which is then reused. It is not intended for drinking water.
Design
- self-supporting polyethylene monobloc with a robust ribbed structure, black as standard
- length 2460 mm, width 2100 mm, height 1300–1810 mm depending on the extension setting
- weight 190 kg – much lighter than concrete tanks, which makes installation easier
- temperature range from −50 °C to +60 °C
- inlet and outlet for 110 mm pipe
- extension with lockable cover included, can be shortened along the marked cutting lines
Installation and maintenance
The tank is carefully lowered onto a compacted bed or concrete slab and surrounded with 4–8 or 8–16 mm gravel. The backfill is compacted by hand in layers of about 30 cm while the tank is gradually filled with water to one third and then to two thirds of its height. The soil cover above the tank should generally not exceed 100 cm and the surface above it is suitable only for occasional foot traffic. With a high groundwater table or in clay soil, the installation method must be agreed with a designer. Filters and tightness should be checked about once a year, and settled sludge removed roughly every 5 years.
Technical data
| Code | S064 |
| Manufacturer | IVAR |
| Type | IVAR.FLAT-3000 |
| Capacity | 3000 l |
| Installation | underground, low-profile tank |
| Material | polyethylene (monobloc), black |
| Length × width | 2460 × 2100 mm |
| Height with extension | 1300–1810 mm |
| Weight | 190 kg |
| Inlet / outlet | 110 mm pipe |
| Temperature range | −50 to +60 °C |
| Drinking water | not suitable |
Frequently asked questions
Can I store drinking water in the tank?
No, the FLAT tank is intended for rainwater and non-potable service water. It is not suitable for drinking water.
Is the extension included?
Yes, the extension with lockable cover is supplied together with the tank. It is fixed with the supplied screws and seal and, if necessary, can be shortened along the cutting lines.
Can vehicles drive or can I build over the tank?
No. No construction is permitted on the surface above the tank; only occasional foot traffic is allowed.
Additional parameters
| Category: | IVAR.ELCU - below-ground plastic tanks |
|---|---|
| Warranty: | 2 years |
| Weight: | 190 kg |
| Type: | tank / vessel |
| Code: | S064 |
| Manufacturer: | IVAR |
| Type: | IVAR.FLAT-3000 |
| Capacity: | 3000 l |
| Installation: | underground, low-profile tank |
| Material: | polyethylene (monobloc), black |
| Length × width: | 2460 × 2100 mm |
| Height with extension: | 1300–1810 mm |
| Weight: | 190 kg |
| Inlet / outlet: | 110 mm pipe |
| Temperature range: | −50 to +60 °C |
| Drinking water: | not suitable |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!
IVAR designs, develops and manufactures highly energy-efficient heating and plumbing systems. We have over 10,000 catalogue items - mass-produced products and unique items - in addition to customised systems and combinations of complex products. And it’s all “Made in Italy”.
Vision
To make life easier for our clients, our clients' customers and our employees, thanks to our ability to be constantly innovative.
Mission
To design and manufacture advanced hydronic solutions that reduce installation complexity and energy consumption.
“Made in Italy” adds value
IVAR has been producing heating and plumbing system components since 1985: valves for heating bodies, direct heat metering modules, heat cost allocators, pipes and fittings, substations for heating systems, distribution manifolds, radiant panel systems, and components for solar and geothermal systems. And it’s all “Made in Italy”.
Over 200 people are employed at our manufacturing facilities in Prevalle (in northern Italy’s Brescia province). The site has been designed to streamline our many production and operational stages.
The Italian headquarters also acts as a hub for the wider IVAR Group, set up with the goal of distributing products beyond Italy’s borders. The group now has 11 branches, in Australia, Belgium, China, Germany, the United Kingdom, the Czech Republic, Romania, Slovakia, Spain, the United States and Tunisia.
Know How
Research, development and numerous laboratory tests guarantee that our clients’ requests can be translated into new high-efficiency products.
The stages required for production take place internally, beginning with hot forming, which is carried out at our subsidiary Valmon Stampati. Our continuous implementation of projects under the Industry 4.0 initiative also allows us to take full advantage of new releases in technology and IT to improve our manufacturing efficiency.
As a company, IVAR is constantly evolving. Every day, we invest in strengthening our products, in improving our production processes and in attaining new patents and certifications.