DUAL INVERTER split air conditioner IVAR.XREVO-18D – 2 wall units, cooling 4.9 kW / heating 5.0 kW
Code: I07011165Product detailed description
Configuration and capacity
The IVAR.XREVO-18D is a DUAL-type inverter air conditioner from the Italian manufacturer EMMETI in which two wall-mounted indoor units connect to a single outdoor unit X-REVO-1824DE with a rotary compressor: the X-REVO-0924W with 2.60 kW cooling capacity and the X-REVO-1224W with 3.10 kW. The inverter continuously varies the total nominal cooling capacity of 4.9 kW within 1.40–6.20 kW. In heating mode the system works as an air-to-air heat pump – at -10 °C outdoors it supplies 5.0 kW, and 5.90 kW nominal at 7 °C (1.50–6.60 kW).
Energy efficiency
- cooling: energy class A++, SEER 7.1, annual electricity consumption 242 kWh
- heating: energy class A++, SCOP 4.6, annual electricity consumption 1518 kWh
- EER 3.86 and COP 4.13 at nominal conditions
- R32 refrigerant, charge 1.05 kg (0.71 t CO2 equivalent)
Equipment and control
Commands are given with the infrared remote control: cooling COOL, heating HEAT, dehumidification DRY, ventilation FAN and automatic SMART mode, set temperature 16–30 °C. There are also SUPER for rapid cooling or heating, QUIET mode, ECONOMY mode, the SLEEP night programme, a TIMER, I FEEL with a temperature sensor in the remote control, 8 °C maintenance in heating mode, the CLEAN mode and automatic restart with the previous settings after a power failure. Smartphone control via the ConnectLife app requires the WiFi controller I07917566, sold separately, which connects to the control board of the indoor unit. The indoor units have a sound pressure of 38–24 dB(A) and an airflow of up to 600 m³/h, and each removes 1.0 l of water per hour; the outdoor unit reaches a sound pressure of 42 dB(A).
Installation and maintenance
Each indoor unit is connected to the outdoor unit by its own pair of refrigerant pipes 6.35 mm (1/4") and 9.52 mm (3/8"). The run to one indoor unit may be at most 20 m and all runs together 30 m; the height difference between outdoor and indoor unit is at most 15 m, and between the indoor units 7.5 m. The outdoor unit, rated IPX4, cools at outdoor temperatures from -15 to 50 °C and heats from -20 to 24 °C; it runs on single-phase 230 V / 50 Hz (max. current 11.0 A). R32 refrigerant is flammable, so installation, commissioning and servicing must be carried out only by a qualified technician. The air filters are cleaned every 100 operating hours, about every two weeks in dusty environments; the manufacturer recommends a check of the complete system every two years.
Measurement conditions: cooling at 27 (19) °C indoors and 35 °C outdoors, heating at 20 °C indoors and -10 °C outdoors.
Technical data
| Code | I07011165 |
| Manufacturer | EMMETI (Italy) |
| Type | IVAR.XREVO-18D |
| Design | split DUAL, 2 wall-mounted indoor units + 1 outdoor unit |
| Size | 18 (9 + 12) kBtu/h |
| Cooling capacity (range) | 4.9 kW (1.40–6.20 kW) |
| Heating capacity at -10 °C | 5.0 kW |
| Energy class cooling / heating | A++ / A++ |
| SEER / SCOP | 7.1 / 4.6 |
| Refrigerant | R32, 1.05 kg |
| Power supply | 230 V / 1 ph / 50 Hz |
| Indoor units | X-REVO-0924W + X-REVO-1224W, each 790 × 253 × 198 mm, 7 kg |
| Outdoor unit | X-REVO-1824DE |
| Max. pipe length / height difference | 20 m per unit, 30 m in total / 15 m |
| Outdoor unit dimensions and weight (W × H × D) | 900 × 588 × 338 mm, 35 kg |
Frequently asked questions
Which indoor units are included in the IVAR.XREVO-18D system?
Two wall units: the X-REVO-0924W with 2.60 kW cooling capacity and the X-REVO-1224W with 3.10 kW. Both connect to the shared outdoor unit X-REVO-1824DE.
How long can the pipes to the indoor units be?
Up to 20 m to one indoor unit and up to 30 m for all runs together. The height difference between outdoor and indoor unit may be up to 15 m, and between the indoor units up to 7.5 m.
Does the system also heat in winter?
Yes, it works as an air-to-air heat pump and delivers 5.0 kW at -10 °C outdoors (class A++, SCOP 4.6). The outdoor unit heats down to an outdoor temperature of -20 °C.
How often should the indoor unit filters be cleaned?
Every 100 operating hours, about every two weeks in dusty environments. Vacuuming the filter is enough; if it is very dirty, wash it in lukewarm water and let it dry in the shade.
Additional parameters
| Category: | wall-mounted air conditioners |
|---|---|
| Warranty: | 2 years |
| Type: | indoor + outdoor unit set |
| Code: | I07011165 |
| Manufacturer: | EMMETI (Italy) |
| Type: | IVAR.XREVO-18D |
| Design: | split DUAL, 2 wall-mounted indoor units + 1 outdoor unit |
| Size: | 18 (9 + 12) kBtu/h |
| Cooling capacity (range): | 4.9 kW (1.40–6.20 kW) |
| Heating capacity at -10 °C: | 5.0 kW |
| Energy class cooling / heating: | A++ / A++ |
| SEER / SCOP: | 7.1 / 4.6 |
| Refrigerant: | R32, 1.05 kg |
| Power supply: | 230 V / 1 ph / 50 Hz |
| Indoor units: | X-REVO-0924W + X-REVO-1224W, each 790 × 253 × 198 mm, 7 kg |
| Outdoor unit: | X-REVO-1824DE |
| Max. pipe length / height difference: | 20 m per unit, 30 m in total / 15 m |
| Outdoor unit dimensions and weight (W × H × D): | 900 × 588 × 338 mm, 35 kg |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!