Thermia ITEC E-STANDARD 16 (ITEC E-S 16) air-to-water heat pump – 3.4–16 kW, flow temperature up to 65 °C

Code: IHP086L4756
Not rated Rating details
14 971,56 € –20 %
Tepelné čerpadlo vzduch/voda Thermia ITEC E-STANDARD 16 (ITEC E-S 16) – 3,4–16 kW, výstup až 65 °C
14 971,56 € –20 % 11 977,25 € / pcs 9 737,60 € excl. VAT Measure price:
International delivery
In stock at supplier

Detailed information

Product detailed description

ITEC E-STANDARD 16 (ITEC E-S 16) is a Thermia inverter heat pump from the IVAR.HP iTec E range for family houses and apartments – for new builds as well as renovated buildings with a heat loss of up to 19 kW. It consists of a compact outdoor unit with an output of 3.4–16 kW and an indoor unit in the STANDARD version. The compressor's frequency inverter continuously adapts the output to the current heat loss of the house.

STANDARD indoor unit

The STANDARD version contains only the control system with display – a 380 × 204 × 600 mm cabinet weighing 18 kg, 230 V supply, 10 A circuit breaker. The circulation pump, diverter valve, backup heater and DHW cylinder are not included and are provided according to the design. It is used mainly in renovations where the original system components remain, or in new builds without domestic hot water production by the heat pump.

Output and efficiency

  • SCOP 4.48 at 35 °C (underfloor heating) and 3.53 at 55 °C (radiators) for the average climate
  • COP 4.42 at A7/W35, energy class A+++ at 35 °C and A++ at 55 °C
  • flow temperature +15 to +65 °C, heating and DHW production down to an outdoor temperature of −25 °C
  • cooling as standard – 14 kW at A35/W18 (SEER 5.31), including a signal for the cooling/heating changeover valve
  • R32 refrigerant with GWP 675 (charge 2.2 kg), BLDC twin rotary compressor, electronic expansion valve, stainless steel plate condenser

Outdoor unit

Dimensions 940 × 330 × 1420 mm (W × D × H), weight 111 kg, 1" male-threaded heating water connections. Power supply 400 V 3~N 50 Hz, circuit breaker 16 A. The sound pressure level at a distance of 4 m is 49 dB(A), sound power 66 dB(A). The unit is anchored to a solid foundation and must not stand in an enclosed space; defrost condensate is drained through a heated drain, never into the sewer.

System design

  • at least 320 l of heating water must always be available in the system for safe defrosting
  • nominal flow 16 l/min, minimum pipe size 35 mm; the flow sensor is included in the delivery
  • the controller handles one direct and one mixed circuit; with an expansion card a second mixed circuit or pool heating
  • photovoltaic integration via Smart Grid (optional accessory); the HPC software is recommended for sizing

Installation: Installation, electrical connection and work on the refrigerant circuit with the mildly flammable R32 refrigerant may only be carried out by qualified specialists.

Technical data

CodeIHP086L4756
ManufacturerThermia (IVAR.HP iTec E range)
TypeITEC E-S 16
Indoor unitSTANDARD – control system
Heating output3.4–16 kW
Cooling output (A35/W18)14 kW
SCOP 35 °C / 55 °C (average climate)4.48 / 3.53
COP (A7/W35)4.42
Energy class 35 °C / 55 °CA+++ / A++
Flow temperature+15 to +65 °C
Outdoor temperature for heating−25 to +35 °C
RefrigerantR32, 2.2 kg
Outdoor unit power supply400 V 3~N 50 Hz
Sound pressure level at 4 m49 dB(A)
Outdoor unit W × D × H, weight940 × 330 × 1420 mm, 111 kg

Frequently asked questions

What is included in the delivery?
The outdoor unit with condensate drain elbow, the STANDARD indoor unit, a ball valve with filter, an outdoor temperature sensor, a flow sensor and documentation. Connection fittings and flexible hoses are ordered separately as accessories.

Can the STANDARD version also produce hot water?
The STANDARD indoor unit contains only the control system – it has no circulation pump, diverter valve or cylinder; these components are added according to the design. If you want the DHW components in one cabinet, choose the PLUS version (with a separate cylinder) or TOTAL.

Can the heat pump also cool?
Yes, the cooling function is included in the basic version; the cooling output is 14 kW at A35/W18. Cooling pipework must be insulated with vapour-tight insulation to prevent condensation.

What maintenance does the heat pump need?
Check the heating system pressure once a month (0.8–1.5 bar), the safety valves at least four times a year and clean the dirt filter twice a year. Keep the outdoor unit free of snow, ice and leaves.

Additional parameters

Category: air / water heat pumps
Warranty: 2 years
Type: heat pump
Heat pump type: air – water
Heating output: 15.1 – 25 kW
Code: IHP086L4756
Manufacturer: Thermia (IVAR.HP iTec E range)
Type: ITEC E-S 16
Indoor unit: STANDARD – control system
Heating output: 3.4–16 kW
Cooling output (A35/W18): 14 kW
SCOP 35 °C / 55 °C (average climate): 4.48 / 3.53
COP (A7/W35): 4.42
Energy class 35 °C / 55 °C: A+++ / A++
Flow temperature: +15 to +65 °C
Outdoor temperature for heating: −25 to +35 °C
Refrigerant: R32, 2.2 kg
Outdoor unit power supply: 400 V 3~N 50 Hz
Sound pressure level at 4 m: 49 dB(A)
Outdoor unit W × D × H, weight: 940 × 330 × 1420 mm, 111 kg