Thermia MEGA S-E (IVAR.HP) ground-source heat pump – 10–33 kW, DHW valve and backup heater, up to 65 °C
Code: IHP205218Product detailed description
Thermia MEGA S-E is an inverter brine-to-water heat pump from the IVAR.HP MEGA range designed for larger buildings and commercial use. The compressor with frequency inverter steplessly varies the output within 10–33 kW (B0/W35) according to the momentary heat demand, so the unit is designed to cover 100 % of the annual heat demand. The flow temperature reaches up to 65 °C, making it suitable for new builds and renovations alike.
Functions
- heating, cooling and domestic hot water production in one unit
- HGW – hot water is heated via a hot gas (superheated vapour) exchanger simultaneously with space heating
- GENESIS control system with colour touch display, up to 5 mixed circuits, WCS and TWC technologies
- built-in web server for Thermia Online remote monitoring, Modbus for the building management system (BMS), Smart Grid for photovoltaics
- cascade connection of multiple units with practically no limit, up to the MW range
S-E version
Compared with MEGA S, the S-E version has a built-in heating/DHW diverter valve and an electric backup heater with three steps of 5/10/15 kW. A Cu 35 mm hot water connection has been added; the other connections correspond to MEGA S.
Technology and efficiency
Quiet Danfoss scroll compressor with speed control, electronic expansion valve, stainless steel plate heat exchangers and energy class A circulation pumps; a special design with rubber compensators minimises vibration. R410A refrigerant, charge 3.9 kg. At B0/W35 it delivers 20.18 kW with a COP of 4.73; the seasonal SCOP is 5.72 (35 °C) and 4.33 (55 °C) according to EN 14825 for the cold climate, energy class A+++. Sound power level 41–56 dB(A).
Installation
The unit measuring 692 × 796 × 1652 mm (W × D × H, without connection stubs) and weighing 309 kg is placed level on a concrete floor at least 100 mm thick, away from room corners and walls adjoining noise-sensitive rooms. Connections: antifreeze 42 mm, heating system 35 mm, hot gas circuit 28 mm. A filter with a mesh of max. 0.7 mm belongs in the heating return and in the antifreeze supply, and connection with flexible hoses is recommended. Power supply 400 V 3N~, circuit breaker 32/40/50 A, maximum pressure of both circuits 6 bar.
Note: The HPC 2 calculation software is used for the design. Installation, electrical connection and commissioning must be carried out by an authorised specialist.
Technical data
| Code | IHP205218 |
| Manufacturer | Thermia (IVAR.HP MEGA range) |
| Type | MEGA S-E |
| Output range (B0/W35) | 10–33 kW |
| Heating output / COP (B0/W35) | 20.18 kW / 4.73 |
| SCOP 35 °C / 55 °C (cold climate) | 5.72 / 4.33 |
| Energy class 35 °C / 55 °C | A+++ / A+++ |
| Max. heating water temperature | 65 °C |
| Antifreeze temperature | −10 to +20 °C |
| Refrigerant | R410A, 3.9 kg |
| Power supply / circuit breaker | 400 V 3N~ / 32/40/50 A |
| Connections antifreeze / heating / hot gas | 42 / 35 / 28 mm |
| Dimensions W × D × H (without stubs) | 692 × 796 × 1652 mm |
| Weight | 309 kg |
| Backup heater | 5 / 10 / 15 kW |
Frequently asked questions
Are the connection fittings included in the delivery?
No. The package contains the heat pump, documentation, a set of noise-damping panels and a sensor set (outdoor sensor and flow line sensor). The IVAR.TER-PS connection fittings are ordered separately – the code for this model is IHP08645680. With MEGA S-E, the Cu 35 mm hot water connection must also be connected separately.
Can MEGA also be used with a water-to-water source?
Yes, but the water-to-water version requires a custom-designed intermediate heat exchanger and a flow sensor. With an additional EM3 card, the submersible source pump can be controlled by a 0–10 V signal according to the temperature difference across the intermediate exchanger.
Which antifreeze is used in the primary circuit?
The manufacturer specifies an ethanol-water solution with a freezing point of −17 °C (±2 °C). Check local regulations before use; the maximum working pressure of the antifreeze circuit is 6 bar.
Additional parameters
| Category: | ground / water heat pumps |
|---|---|
| Warranty: | 2 years |
| Weight: | 309 kg |
| Type: | heat pump |
| Heating output: | over 25 kW |
| Code: | IHP205218 |
| Manufacturer: | Thermia (IVAR.HP MEGA range) |
| Type: | MEGA S-E |
| Output range (B0/W35): | 10–33 kW |
| Heating output / COP (B0/W35): | 20.18 kW / 4.73 |
| SCOP 35 °C / 55 °C (cold climate): | 5.72 / 4.33 |
| Energy class 35 °C / 55 °C: | A+++ / A+++ |
| Max. heating water temperature: | 65 °C |
| Antifreeze temperature: | −10 to +20 °C |
| Refrigerant: | R410A, 3.9 kg |
| Power supply / circuit breaker: | 400 V 3N~ / 32/40/50 A |
| Connections antifreeze / heating / hot gas: | 42 / 35 / 28 mm |
| Dimensions W × D × H (without stubs): | 692 × 796 × 1652 mm |
| Weight: | 309 kg |
| Backup heater: | 5 / 10 / 15 kW |
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!