Product sorting

6 items total

List of products

Vykurovacia technika Termostatický vyvažovací ventil - pre rozvody TV - 1/2"F; regulácia teploty
–20 %
139,73 €

Thermostatic balancing valve - for DHW systems - 1/2"F; temperature control

506187
Vykurovacia technika Termostatický vyvažovací ventil - pre rozvody TV - 1/2"F; regulácia teploty a elektronický BY-PASS
–20 %
170,23 €

Thermostatic balancing valve - for DHW systems - 1/2"F; temperature control and...

506189
Vykurovacia technika Termostatický vyvažovací ventil - pre rozvody TV - 1/2"F; regulácia teploty a mechanický BY-PASS
–20 %
170,23 €

Thermostatic balancing valve - for DHW systems - 1/2"F; temperature control and...

506188
Vykurovacia technika Termostatický vyvažovací ventil - pre rozvody TV - 3/4"F; regulácia teploty
–20 %
139,73 €

Thermostatic balancing valve - for DHW systems - 3/4"F; temperature control

507036
Vykurovacia technika Termostatický vyvažovací ventil - pre rozvody TV - 3/4"F; regulácia teploty a elektronický BY-PASS
–20 %
170,23 €

Thermostatic balancing valve - for domestic hot water - 3/4"F; temperature control...

507038
Vykurovacia technika Termostatický vyvažovací ventil - pre rozvody TV - 3/4"F; regulácia teploty a mechanický BY-PASS
–20 %
170,23 €

Thermostatic balancing valve - for domestic hot water - 3/4"F; temperature control...

507037

Listing controls

6 items total

Thermostatic Balancing Valves - for DHW Circuits

IVAR.RTV A, IVAR.RTV B, IVAR.RTV C
  • control range +35 °C to +60 °C
  • the valve is designed to regulate flow and maintain a constant DHW temperature
  • IVAR.RTV A - temperature control
  • IVAR.RTV B - temperature control and mechanical BY-PASS for thermal disinfection
  • IVAR.RTV C - temperature control and electronic BY-PASS for thermal disinfection
  • material: CW617N brass

Frequently Asked Questions

  • What are thermostatic balancing valves used for in DHW circuits? They automatically balance flow in the individual branches of the hot water circulation so that the set temperature is maintained throughout the circuit regardless of the distance from the source.
  • What is the difference between the mechanical and electronic BY-PASS? The mechanical BY-PASS opens purely based on the temperature of the medium, while the electronic BY-PASS additionally allows controlled thermal disinfection of the circuit against legionella bacteria.
  • Where are these valves fitted in the circulation circuit? They are fitted at the end of the individual branches of the hot water circulation pipework, usually before they join the common return pipe to the storage tank.
Vytvořil Shoptet | Design Shoptak.cz.