Decentralized ventilation units and accessories
For IVAR.HRC decentralised ventilation units with heat recovery, this section offers spare parts and accessories in a 160 mm diameter. The external design grille finishes the wall opening on the façade, while the heat recovery and filter inserts are replaced during maintenance or refurbishment. The parts fit HRC units of this diameter only.
Bestsellers
Product sorting
List of products
Heat recovery ventilation unit for classrooms, offices and commercial premises...
Wall-mounted heat recovery ventilation unit for classrooms, offices and commercial...
Heat recovery ventilation unit for classrooms, offices and commercial premises...
Wall-mounted heat recovery ventilation unit for classrooms, offices and commercial...
High-performance single-room ventilation unit with a ceramic heat exchanger of up...
High-performance single-room ventilation unit with a ceramic heat exchanger of up...
Single-room ventilation unit with a ceramic regenerative heat exchanger of up to...
Listing controls
analog version HRC S - IVAR.HRC SM, IVAR.HRC SS
- the Master unit is supplied with controls, the Slave unit without controls
- supply voltage 230 V, a 12 V transformer is included in the delivery
- the Master unit can control up to 3 Slave units
electronic version HRC E - IVAR.HRC EM
- the Master unit is supplied with a remote control, the Slave unit without controls
- supply voltage 230
- the Master unit can control up to 11 Slave units
wall mounting template - IVAR.HRC MS
- for easy disassembly without loosening screws, 230 x 230 mm
- for quick inspection of the unit when needed
- supplied including mounting screws
outdoor aesthetic grille - IVAR.HRC M
- used to terminate the ducting on the building façade
- antistatic material resistant to UV radiation
replaceable recovery insert - IVAR.HRC VR
- included in the delivery of the HRC unit
- this is a spare part
- alternating bidirectional flow
- ceramic material with low pressure loss
replaceable filter insert - IVAR.HRC VF
- easily replaceable G3
- with low pressure loss
Frequently Asked Questions
- What is the IVAR.HRC decentralized ventilation unit? A compact unit installed directly into the perimeter wall of a room, which ventilates and recovers heat without the need for ducting throughout the building.
- What is the difference between HRC S and HRC E? HRC S is the analog version, HRC E is the electronic version with more advanced operation control.
- What does the Master and Slave designation mean? The Master unit contains the controls, the Slave unit has no controls and is intended to work together with the Master unit in a multi-point solution.
- How often does the filter insert need to be replaced? The interval depends on the dust level in the environment, typically 3-6 months - the unit signals when a replacement is needed.